نتایج جستجو برای: ion detection
تعداد نتایج: 762730 فیلتر نتایج به سال:
Evaluation of selected-ion storage ion-trap mass spectrometry for detecting urinary anabolic agents.
Limits of detection are important issues for GC/MS screening for anabolic agents and for confirmation of various drugs of abuse. We compared a quadrupole ion trap (QIT) operated in two different selected-ion storage modes and a quadrupole mass filter (QMF) operated in the selected-ion monitoring mode. Results with the model compound tetrachlorobenzene indicate that, for simultaneous monitoring ...
New rhodamine based molecules have been designed as dual probes for the ppb-level selective detection of Hg(2+) and F(-) ions in aqueous medium at physiological pH 7.4. The probes have been designed in such a way to utilize both the properties of the metal ion induced 'turn-on' detection mechanism of the spirolactam ring opening of the rhodamine moiety and the reaction based cleavage of the O-s...
We present a general technique for precision spectroscopy of atoms that lack suitable transitions for efficient laser cooling, internal state preparation, and detection. In our implementation with trapped atomic ions, an auxiliary "logic" ion provides sympathetic laser cooling, state initialization, and detection for a simultaneously trapped "spectroscopy" ion. Detection is achieved by applying...
Electronic devices that are designed to use the properties of single atoms such as donors or defects have become a reality with recent demonstrations of donor spectroscopy, single photon emission sources, and magnetic imaging using defect centers in diamond. Ion implantation, an industry standard for atom placement in materials, requires augmentation for single ion capability including a method...
due to extraordinary large amount of information and daily sharp increasing claimant for ui benefits and because of serious constraint of financial barriers, the importance of handling fraud detection in order to discover, control and predict fraudulent claims is inevitable. we use the most appropriate data mining methodology, methods, techniques and tools to extract knowledge or insights from ...
in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...
in order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (npdbh) was used as an ionophore. this electrode responds to sr (ii)ion with a sensitivity of 28.2 ± 0.5 mv/decade over the range 1.0 x 10-6 to 1.0 mat ph 3.0-10.0. thelimit of detection was 2.4 x 10-7 m. the influences of membrane composition, the ph of the t...
in this study, a sensitive method of dispersive liquid phase microextraction based on ion-pair combined with the flame atomic absorption spectrometry was proposed for the determination of trace ni(ii) using aliquat 336-chloride as ion pair agent. several factors which have effect on the microextraction efficiency of ni(ii), such as ph, extraction and dispersive solvent type and their volume, c...
A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...
A radioactive ion beam of 6He produced via the 7Li(p,2p)6He reaction with typical intensity of 3 × 106 ions/see was elastically scattered from LiF(Au) targets. Elastic scattering of 6He at Elab=27 MeV with 197Au have been measured in the angular range of 6º-72º in the laboratory system employing LEDA and LAMP detection system. Optical Model calculations have been used to fit the data .
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید