purpose: to compare visual outcomes and surgical complications of three phakic intraocular lenses (piols); artisan, artiflex and the implantable collamer lens (icl) for correction of moderate to high myopia. methods: in this historical cohort study, 112 myopic eyes that were operated between 2005 and 2010 and implanted with one of these three piols were evaluated (artisan 40 eyes, artiflex 36 e...
purpose: to evaluate visual function in patients with different types of light-filtering intraocular lenses (iols) methods: in this prospective comparative clinical study cataract patients with different types of iols in khatam-al-anbia eye hospital, mashhad were enrolled and followed for three months postoperatively. corrected distance visual acuity (cdva), color discrimination under photopic ...
A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL) because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and ...
BACKGROUND Biofilm formation of Staphylococcus epidermidis is a major etiological factor of inducing device-related infections. OBJECTIVES The ability of biofilm formation by the S. epidermidis was assessed in vitro on two brands of foldable (hydrophilic) and two brands of rigid (hydrophobic) intraocular lens materials in order to investigate the role of lens material in postoperative endopht...
PURPOSE To compare the reliability and accuracy of intraocular pressure (IOP) measured while wearing soft contact lenses (SCLs) using a non-contact tonometer (NCT), Goldmann applanation tonometer (GAT), iCare rebound tonometer (RBT) and the Tono-Pen XL. METHODS Twenty-six healthy subjects were examined. The IOP was measured using NCT, GAT, RBT, and the Tono-Pen XL, while the subjects wore SCL...
Dear Sir, This letter is to alert about the danger of carrying out biometric calculations for the intraocular lens without being aware that the patient may be using a contact lens. This warning is valid even when the highest precision research technology is being utilised. At present, errors in the calculation of the intraocular lens (IOL) are the most frequent cause of lens exchanges as well a...
Purpose: The objective of this study was to evaluate the outcome of Acrysof Toric intraocular lenses (IOLs) implantation in cataract surgery for the correction of regular corneal astigmatism. Methods: Twenty eyes of 16 patients with cataract and regular corneal astigmatism of 1.00-4.00 diopter (D) underwent surgery. Depending on the amount of corneal astigmatism, an Acrysof Toric IOL of type SN...
Intraocular lens (IOL) opacification is a rare complication following cataract surgery. IOL has been reported in various types of IOL, including polymethylmethacrylate, hydrophobic acrylic, and hydrophilic acrylic lenses. This increasingly recognized clinical entity could result range symptoms, such as reduced or foggy vision, glare, halos around bright light. Not uncommonly, exchange necessita...