نتایج جستجو برای: high frequency transformer

تعداد نتایج: 2397238  

2007
Duo Chen Haiyu Yu Jiansheng Yuan

The MV/LV transformer without a tank in the underground substation can produce remarkable interference with the computer Cathode-Ray Tube (CRT) displayers above the ground, because of the generated power frequency magnetic field. To resolve such problem, a tank with high conductivity or/and high permeability is needed to enclose the transformer. To evaluate the shielding effectiveness, the fini...

Journal: :Magnetism 2022

The design of medium- to high-frequency power electronics transformer aims not only minimize the loss in windings and core, but its heat removal features should also allow optimal use both core copper. feature (e.g., thermal conduction) a is complex because there exist multiple centers. bulk total concentrated around small segment assembly where are overlaid. primary winding most constrained th...

2012
R.Samuel Rajesh Babu Joseph Henry

This paper presents a comparative analysis of DC-DC Converters for Renewable Energy System. It has been proved that DC-DC converter with transformer is suitable for Electrolyser application. Due to high input and output voltage differences, the topologies with a high frequency voltage matching transformer are analyzed. The comparative analysis is done with and without Transformer topology in or...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تحصیلات تکمیلی صنعتی کرمان - پژوهشکده برق و کامپیوتر 1390

a phase-locked loop (pll) based frequency synthesizer is an important circuit that is used in many applications, especially in communication systems such as ethernet receivers, disk drive read/write channels, digital mobile receivers, high-speed memory interfaces, system clock recovery and wireless communication system. other than requiring good signal purity such as low phase noise and low spu...

2009
Hanif Tavakoli

Frequency response analysis (FRA) is a method which is used to detect mechanical faults in transformers. The FRA response of a transformer is determined by its geometry and material properties, and it can be considered as the transformer’s fingerprint. If there are any mechanical changes in the transformer, for example if the windings are moved or distorted, its fingerprint will also be changed...

2014
Mihail Digalovski Krste Najdenkoski Goran Rafajlovski

Transformers are normally designed and built for use at rated frequency and sinusoidal load current. A non-linear load on a transformer leads to harmonic power losses which cause increased operational costs and additional heating in transformer parts. It leads to higher losses, early fatigue of insulation, premature failure and reduction of the useful life of the transformer. To prevent these p...

2013
AKSHAY A. PANDYA

Sweep frequency response analysis is a major advance in transformer condition analysis. Frequency response is performed by applying a low voltage signal of varying frequencies to the transformer windings and measuring both the input and output signals. The ratio of these two signals gives the required response. This ratio is called the transfer function of the transformer from which both the ma...

2007
W. H. Tang S. He Q. H. Wu

This paper presents a new approach to identify distributed parameters of a lumped-element model for a power transformer. A simplified circuit of a lumped-element model is developed to calculate frequency responses of transformer windings in a wide range of frequency domain. In order to seek optimal parameters of the simplified circuit of the transformer, an intelligent learning technique, based...

2003
Bjørn Gustavsen

This paper describes a procedure for frequency dependent modeling of power transformers from measured terminal characteristics. The admittance matrix is measured in the frequency domain using a network analyzer and a dedicated measurement setup. Subsequent approximation of the admittance matrix with rational functions using Vector Fitting gives an EMTP-type compatible model suitable for transie...

2007
Y. Z. Xu J. T. Watt

Spiral inductors fabricated using a 90nm CMOS process have been characterized and analyzed. The extracted series resistance increases with frequency and temperature. The extracted resistance temperature coefficient exhibits a strong dependence on operating frequency. It gradually decreases with frequency and is different from the results using DC temperature coefficients. A single π-model is us...