INTRODUCTION Dialyzer reprocessing machines have replaced human labor in preparing re-usable dialyzers. It also made the process of total cell volume (TCV) measurement become faster. Nevertheless, there has been a lack of data on efficacy of weight evaluation on TCV by machine compared to volume evaluation by the conventional method. The aim of this study was to evaluate the efficacy of TCV mea...
BACKGROUND Little information is available regarding which type of dialyzer membrane results in good prognosis in patients on chronic hemodialysis. Therefore, we conducted a cohort study from a nationwide registry of hemodialysis patients in Japan to establish the association between different dialyzer membranes and mortality rates. METHODS We followed 142,412 patients on maintenance hemodial...
A number of bacterial cytokine-inducing substances (CIS) such as lipopolysaccharides (LPS) and exotoxins have been detected in dialysate and may contribute to inflammation in hemodialysis patients. Short DNA fragments, oligodeoxynucleotides (ODN) of 6 to 20 nucleotides, are able to bind to Toll-like receptors and are stimulatory on immune cells. ODN induce natural killer cell activity and induc...
Although dialyzer reuse for home hemodialysis (done by patients at home) has been in practice since the 1960s, it is now almost completely abandoned. The need for dialyzer reuse resurfaced with the renewed interest in daily/nightly forms of home hemodialysis and the associated increase in operating costs. We describe a method of dialyzer reuse based on reprocessing of dialyzers at the center, a...
BACKGROUND AND OBJECTIVES The fixed antibacterial combination of ampicillin and sulbactam is frequently used for various infections. Intact kidneys eliminate approximately 71% of ampicillin and 78% of sulbactam. Patients on thrice-weekly low-flux hemodialysis exhibit an ampicillin t(1/2) of 2.3 hours on and 17.4 hours off dialysis. Despite its frequent use in intensive care units, there are no ...
BACKGROUND/AIMS Although high-flux (HF) dialyzers with enhanced membrane permeability are widely used in current hemodialysis (HD) practice, urea kinetic modeling is still being applied to indicate the adequacy of both low-flux (LF) and HF HD. In comparison with urea (molecular weight, 60 Da) and beta(2)-microglobulin (beta(2)MG, 12 kDa), cystatin C (CyC, 13 kDa) is a larger molecule that has a...
Intravenous desferrioxamine (DFO) is the method commonly used to treat aluminum toxicity. This laboratory has developed a hollow fiber device with immobilized DFO, an "Aluminum DFO-HP" (DFO-HP), for the purpose of removing aluminum without the chelator (DFO) entering the blood. With Food and Drug Administration approval, a polysulfone DFO-HP, placed in the extracorporeal circuit in series with ...
Blood and dialyzer membrane interaction can cause significant thrombocytopenia through the activation of complement system. The extent of this interaction determines the biocompatibility of the membrane. Although the newer synthetic membranes have been shown to have better biocompatibility profile than the cellulose-based membranes, little is known about the difference in biocompatibility betwe...