نتایج جستجو برای: high energy radiotherapy

تعداد نتایج: 2617120  

2017
Stephanie Keehan Ryan L. Smith Jeremy Millar Max Esser Michael L. Taylor Peta Lonski Tomas Kron Rick D. Franich

High energy radiotherapy can produce contaminant neutrons through the photonuclear effect. Patients receiving external beam radiation therapy to the pelvis may have high-density hip prostheses. Metallic materials such as those in hip prostheses, often have high cross-sections for neutron interaction. In this study, Thackray (UK) prosthetic hips have been irradiated by 18 MV radiotherapy beams t...

Journal: :Journal of the Korean Medical Association 2008

ژورنال: پیاورد سلامت 2017
ایمانی, آرزو, موسوی انیجدان, سید حسین, میانجی, فریدون, پایدار, رضا, چنگیزی, وحید,

Background and Aim: Estimation of radon density  in underground centers is very important. Considering the use of high-energy medical accelerators, radiotherapy departments are usually located in underground floors. The aim of this study was to evaluate staff exposure to radon gas in these centers in Tehran in 2015-2016. Materials and Methods: This is a descriptive,  cross-sectional survey. In...

Journal: :Communications physics 2021

Abstract Very high energy electron (VHEE) beams have been proposed as an alternative radiotherapy modality to megavoltage photons; they penetrate deeply without significant scattering in inhomogeneous tissue because of their relativistic inertia. However, the depth dose distribution a single, collimated VHEE beam is quasi-uniform, which can lead healthy being overexposed. This be largely overco...

Introduction: The accuracy of dose calculation algorithm (DCA) is highly considered in the radiotherapy sequences. This study aims at assessing the accuracy of five dose calculation algorithms in tissue inhomogeneity corrections, based on the International Atomic Energy Agency TEC-DOC 1583. Material and Methods: A heterogeneous phantom was sc...

Journal: :iranian journal of materials forming 2015
a. khosravifard m. m. moshksar r. ebrahimi

the dynamic behavior of three high manganese steels with very different stacking faultenergy (sfe) values (4-30 mj/m2) were studied using high strain rate torsional tests. the hotrolledmicrostructure of the steel with the lowest sfe of 4 mj/m2 consisted of a duplex mixture ofaustenite and ε-martensite, but those of the other two steels were fully austenitic. the deformedmicrostructures were stu...

E. Esmati, H. Nosrati, H.A. Nedaie, M. Jamali, N. Banaee,

Background: In radiation therapy, peripheral dose or the dose outside the radiotherapy field, is important when anatomical structures with very low dose tolerances are involved. One of these critical organs in pelvic irradiation is testis. The amount of radiation delivered to the testes in radiotherapy must be kept as small as possible, consistent with the limit dose of this organ. The threshol...

Journal: :Journal of the Korean Medical Association 2004

2014
Yoshio Monzen Katsuzo Kiya Takashi Nishisaka

We performed radiotherapy in a 28-year-old patient with Kimura's disease of the orbit. Irradiation with 21.6 Gy was administered to the tumor bed with a single dose of 1.8 Gy in 5 weekly fractions delivered via a high-energy linear accelerator (6-MV X-ray). Complete remission of the tumor and improvements in the neurological findings were achieved. Neither tumor regrowth nor late complications ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید