نتایج جستجو برای: harmonic load modelling

تعداد نتایج: 353246  

Thisstudy presents axially forced vibration of a cracked nanorod under harmonic external dynamically load. In constitutive equation of problem, the nonlocal elasticity theory is used. The Crack is modelled as an axial spring in the crack section. In the axial spring model, the nonrod separates two sub-nanorods and the flexibility of the axial spring represents the effect of the crack. Boundary ...

2013
Mohammad Keivanfard Gholamreza Nemati

In this paper ranking of harmonic distortion of each nonlinear load like economical, ministerial, residential and others include hotels, hospitals, universities and terminals in the HORMOZGAN Province Electrical power Distribution network is determined by using new power quality index which is directly related on harmonic distortion sources in the distribution power system. Then, the ranking of...

This paper investigate the properties of the circulating current and load sharing in parallel microgrid inverters. The existing methods cannot minimize efficient circulating current for the case of nonlinear load. The one-cycle control (OCC) technique and virtual complex impedance loop are included in the proposed controller in order to proper load sharing and reduce the circulating current due...

In this paper, a novel control strategy for a Shunt Active Power Filter (shunt-APF) is proposed. In the proposed control strategy which is based on a new application of the instantaneous reactive power theory, the current injected by the shunt-APF is capable of compensation for the reactive component, the harmonic components and also unbalance of the load current. In this strategy, the shunt-AP...

2013
Gokulananda Sahu Kamala Kanta Mahapatra Subrat Kumar Sahu

This paper investigates the design,analysis and simulation of a Distribution-STATic COMpensator(D-STATCOM) for non-linear load Composite(harmonic and reactive power) compensation on a three phase bus network. Composite compensation is achieved by implementation of a p-q controller, which monitors the load current and injects equal amplitude and opposite phase compensation currents to neutralize...

2012
Rushi R. Desai Amit N. Patel Vinod R. Gupta

The internal faults of transformer can be identified by various techniques. The proposed technique is by the analysis of no-load current and harmonic contents present in it. The no-load current of transformer is non-sinusoidal for sinusoidal input voltage. And hence it contains harmonics in healthy condition of transformer. But if transformer has any internal fault then the no-load current magn...

Journal: :IEEE Transactions on Power Systems 1991

2006
Bhim Singh Vishal Verma

It has been established that shunt active power filters are suitable for compensating harmonics in the current fed type harmonic producing loads, likewise the series active power filter (APF) are considered to be suitable for voltage fed type harmonics-producing load. This paper discusses the indirect current control approach in terms of its simplicity and effectiveness for the operation of a s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید