نتایج جستجو برای: goldmann applanation tonometer

تعداد نتایج: 2316  

2017
Sean McCafferty Garrett Lim William Duncan Eniko T Enikov Jim Schwiegerling Jason Levine Corin Kew

PURPOSE Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics. METHODS A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness,...

Journal: :journal of current ophthalmology 0
سپهر فیضی sepehr feizi محمد پاکروان mohammad pakravan

purpose : to compare intraocular pressure (iop) readings measured by the ocular response analyzer (ora) with those measured by the goldmann applanation tonometer (gat) in keratoconic eyes following penetrating keratoplasty (pkp) and evaluate the influence of anatomical and biomechanical properties of the grafts on the iop measurements methods : in this cross-sectional study conducted on 45 kera...

2014
R Arora H Bellamy MW Austin

PURPOSE To compare intraocular pressure (IOP) measurements, taken using Perkins applanation tonometry (PAT) and Goldmann applanation tonometry (GAT). METHODS 100 eyes of 100 patients underwent Perkins and Goldmann applanation tonometry, with a randomized order of modality, performed by a masked observer. The right eye was measured, for all subjects, and the data used in statistical analysis. ...

2016
Sean McCafferty Garrett Lim William Duncan Eniko Enikov Jim Schwiegerling

PURPOSE We evaluate solutions for an applanating surface modification to the Goldmann tonometer prism, which substantially negates the errors due to patient variability in biomechanics. METHODS A modified Goldmann or correcting applanation tonometry surface (CATS) prism is presented which was optimized to minimize the intraocular pressure (IOP) error due to corneal thickness, stiffness, curva...

Journal: :Benha Medical Journal 2021

Background: Measurement of intraocular pressure is one the most important examination procedures in ophthalmic clinics, IOP an parameter diagnosis glaucoma. There are numerous types tonometers available, it to evaluate differences readings between different tonometers. Goldmann Applanation Tonometers and non-contact Air-Puff largely available clinics.Aim: The purpose this study difference measu...

Journal: :Ophthalmology 2004
Tara L Alvarez Stephen A Gollance Gordon A Thomas Richard J Greene Peter M Marchetto Eugene J Moore Tony Realini Jeffrey M Liebmann Robert Ritch Paul Lama Robert D Fechtner

PURPOSE To evaluate the Proview Eye Pressure Monitor as a medical instrument and as a technique for enabling a patient to obtain an accurate measure of his or her intraocular pressure (IOP). DESIGN An experimental laboratory evaluation and an independent prospective clinical study to test the reproducibility and accuracy of the Proview technique relative to Goldmann applanation tonometry. P...

نمودار تعداد نتایج جستجو در هر سال