نتایج جستجو برای: gel dosimetry nipam

تعداد نتایج: 113003  

Journal: :Medical physics 2001
M Oldham J H Siewerdsen A Shetty D A Jaffray

The increased intricacy of Intensity-Modulated-Radiation-Therapy (IMRT) delivery has created the need for a high-resolution 3D-dosimetry (three-dimensional) system capable of measuring and verifying the complex delivery. Present clinical methods are inadequate being restricted to single points (e.g., ion-chambers) or to 2D planes (e.g., film), and are labor intensive. In this paper we show that...

Journal: :journal of biomedical physics and engineering 0
m. dehghan master student of physics, department of physics, yazd university, yazd, iran h. mokhtari assistant professor of physics, department of physics, yazd university, yazd, iran f. bouzarjomehri associate professor of medical physics, shahid sadoughi university of medical sciences, yazd, iran

background: over recent decades, modern protocols of external beam radio¬therapy and radiation techniques such as intensity-modulated radiotherapy (imrt) have been developed. these methods are extremely sensitive to errors in treatment delivery, so that it is essential to apply a high resolution 3d dosimetry system that has high sensitivity and is capable of measuring and verifying the complex ...

Hasan Nedaie Hossein Hasani, Mahmood Allahverdi Mohammad Hasan Zahmatkesh Saeid Bagheri Sajad Mirzaie

Introduction: In radiotherapy, methods of treatment planning are becoming increasingly more complicated. This requires verification of the doses delivered to increasingly smaller and more precise regions. Radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...

Journal: :iranian journal of radiation research 0
s.m. abtahi university of shahid beheshti, radiation medicine department, p. o. box 19839- 63113, tehran, iran s.m.r. aghamiri university of shahid beheshti, radiation medicine department, p. o. box 19839- 63113, tehran, iran h khalafi nuclear science and technology research institute (nstri), tehran, iran f. rahmani university of shahid beheshti, radiation medicine department, p. o. box 19839- 63113, tehran, iran

background: the aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or pmma), a150 plastic and te- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. materials and methods: thermal neutron fluence, photon dose and epithermal neut...

Journal: :Journal of Physics: Conference Series 2015

Journal: :Journal of Physics: Conference Series 2009

H. Pourbeigi, M.H. Zahmatkesh, Sh. Akhlaghpoor,

Background: Since 1984 MRI gel dosimetry has been introduced as a potential technique for 3D dosimetry. Most of the studies have measured R1 (1/T1) or R2 (1/T2) properties of the gel depending on the gel type. We have studied image intensity change in the Fricke gel by different MRI protocols. Materials and Methods: Gel Dosimeters contain 0.4 mM ferrous sulphate, 1 mM NaCl, 50 mM H2SO4 and 1% b...

2014
L J Schreiner

Since the introduction of volumetric chemical dosimetry with Fricke gel dosimeters in the 1980s, three-dimensional (3D) dosimetry has been a promising technique for the clinic, since it provides a unique methodology for 3D dose measurement of the complex conformal dose distributions achieved by modern techniques such as Intensity Modulated and Volumetric Arc Radiation Therapy. In the last decad...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید