Journal: :Physics in medicine and biology 2007
R P Srivastava C De Wagter

Radiographic or silver halide film is a well-established 2D dosimeter with an unquestioned spatial resolution. But its higher sensitivity to low-energy photons has to be taken into consideration. Metal compensators or physical modulators to deliver intensity modulated radiation therapy (IMRT) are known to change the beam energy spectrum and to produce scattered photons and contaminating electro...

Journal: :Medical physics 2005
Jean M Moran Donald A Roberts Teamour S Nurushev Larry E Antonuk Youcef El-Mohri Benedick A Fraass

An a-Si Active Matrix Flat Panel Imager (AMFPI) prototype developed in-house has been modified to function as an in-phantom dosimetry system providing high resolution two-dimensional (2-D) data. This Active Matrix Flat Panel Dosimeter (AMFPD) system can be used as a replacement device for standard in-phantom dosimeters, such as scanning ion chambers in water, or film in solid water. The initial...

2013
Y. S. Soliman W. B. Beshir A. A. Abdel-Fattah N. M. Ali

A detailed study was performed to investigate the dosimetric characteristics of polyvinyl butyral (PVB) containing 10,12-pentacosadiynoic acid (PCDA) monomer. PCDA monomer undergoes radiation polymerization when subjected to gamma rays inducing change in the absorption spectra in the UV region of the spectrum. Unirradiated film is colourless and has four absorption peaks at 216 nm, 227nm, 241nm...

Journal: :Physics in medicine and biology 2010
Ethan T Butson Tsang Cheung Peter K N Yu Martin J Butson

Ultraviolet radiation dosimetry has been performed with the use of a radiochromic film dosimeter called Gafchromic EBT for solar radiation exposure. The film changes from a clear colour to blue colour when exposed to ultraviolet radiation and results have shown that the colour change is reproducible within ±10% at 5 kJ m(-2) UV exposure under various conditions of solar radiation. Parameters te...

2013
T Juang J Newton S Das J Adamovics M Oldham

Deformable 3D dosimeters have potential applications in validating deformable dose mapping algorithms. This study evaluates a novel deformable PRESAGE® dosimeter and its application toward validating the deformable algorithm employed by VelocityAI. The deformable PRESAGE® dosimeter exhibited a linear dose response with a sensitivity of 0.0032 ΔOD/(Gy/cm). Comparison of an experimental dosimeter...

2015
Masayori Ishikawa Naomi Nagase Taeko Matsuura Junichi Hiratsuka Ryusuke Suzuki Naoki Miyamoto Kenneth Lee Sutherland Katsuhisa Fujita Hiroki Shirato

The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filte...

Fariba Eyni Maryam Atarod, Mohammad Javad Tahmasebi Birgani Nahid Chegeni Seyed Mojtaba Hosseini

Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...

Journal: :The Laryngoscope 2015
Stephanie Misono Kathryn Banks Philippe Gaillard George S Goding Bevan Yueh

OBJECTIVES/HYPOTHESIS Voice rest is frequently recommended following surgical disruption of vocal fold epithelium, but patients report variable adherence to voice rest recommendations. The objective of this study was to assess the clinical utility of an ambulatory vocal dosimeter for measuring adherence to voice rest recommendations. STUDY DESIGN Outcomes research. METHODS Part 1: To determ...

2017
Kananan Utitsarn Nauljun Stansook Michael L. F Lerch Marco Petasecca Anatoly B. Rosenfeld

We evaluate the impact of an air gap and optimization of this air gap for the MP512 silicon detector array when operated in dosimetry mode for small photon field measurements in solid water. We present output factor measurements for 6MV and 10 MV photon beams with the square field sizes ranging from 0.5 to 10 cm2. The size of the air gap above the MP512 detector was changed from 0.5, 1.0, 1.2, ...