Transesophageal pacing and recording is done using specialized or non specialized catheters. There are two different lead types: 1) the pill electrode, connected to a flexible wire, that the patient swallows with water. This pill electrode necessitates patient collaboration. 2) a flexible catheter that can even be used in comatose or intubated patients. The pacing lead, in our cases a bipolar f...
t-wave oversensing occurs when the counter starts giving dual beeps for every cardiac cycle instead of one. this usually happens when the monitoring lead displays a tall t wave, which is also sharp. r wave sensing algorithms of the devices do not sense t wave because the slow rate of the t wave is much less than that of the r wave. but the slow rate of t waves may change with time and also beca...
Figure 1 Two little third-degree skin burns under the breast following use of an external cardiac pacing device. External cardiac pacing devices (ECPDs) are commonly employed in emergency situations. The main indication for their use is untolerated bradycardia, especially in cases where other medical treatments have no effect [1]. Although the efficacy and safety of ECPDs are well documented, a...
BACKGROUND The brain of children in the early period after repair of congenital heart defects with cardiopulmonary bypass (CPB) may be more vulnerable to hemodynamic changes because of impaired cerebral autoregulation. During postoperative testing of the external temporary safety pacer, we performed desynchronizing ventricular pacing (VVI) while monitoring cerebral oxygenation using near-infrar...
P acemakers were developed in the 1950s primarily to treat life-threatening transient heart block after cardiac surgery. These were large external devices connected to epicardial electrodes placed surgically. Although life-sustaining, these devices were plagued by many problems including short battery life, lead failures, and infections, due in part to externalization of part of the system (1)....
The efficacy and safety of a new antitachycardia pacing technique, self-adapting decremental overdrive pacing, was assessed in patients with clinical ventricular tachyarrhythmias who underwent programmed ventricular stimulation and serial drug testing. The three phases of this study involved a learning/experience phase, followed by intrapatient comparison of decremental overdrive pacing with co...
PURPOSE The aim of this study was to investigate whether providing incorrect distance feedback would alter pacing strategies, perceived exertion, and heart rate during 20-km cycling time trials (TT). METHODS Well-trained cyclists (N=15) performed a peak power output (PPO) test, familiarization trial, and four 20-km cycling TT during which they were provided with only distance feedback using 1...
زمینه و هدف: امروزه تعداد قابل توجهی از بیماران قلبی نیازمند ضربان سازهای قلبی میباشند که خود عوارض متعددی از جمله نارسایی دریچهای و قلبی دارد. هدف از این مطالعه مقایسه ایجاد نارسایی دریچههای میترال(دو لتی) و تریکوسپید(سه لتی) به دنبال pacing (تحریک ضربان) از rva (نوک بطن راست) و rvot (مجرای خروجی بطن راست) میباشد. مواد و روشها: در این کارآزمایی بالینی یک سوکور 164 بیماری که به علل اختلال ...