نتایج جستجو برای: electrothermal atomic absorption spectroscopy

تعداد نتایج: 359417  

Journal: :Clinical chemistry 1996
G Heinemann W Vogt

We describe an ultrasensitive and reliable method for determining vanadium in human serum by electrothermal atomic absorption spectrometry. After lyophilization, the serum is digested in acid at high pressure, and the digests are evaporated to a small volume. Vanadium in the digests is complexed with cupferron, extracted, and dried. The residue is redissolved in formic acid, where it is 15-fold...

Journal: :Clinical chemistry 1980
L T Wetzel J U Bell

We describe the electrothermal atomic absorption spectrophotometry of cadmium in rabbit semen collected before and after seven days of subcutaneous administration of 0.5 mg of cadmium per kilogram body weight per day. The analytical technique involves combining an aliquot of an acid-digested semen sample with an equal volume of an (NH4)2HOP4 solution (50 g/L), to allow an increase in charring t...

Journal: :Clinical chemistry 1996
P Bermejo-Barrera A Moreda-Piñeiro T Romero-Barbeito J Moreda-Piñeiro A Bermejo-Barrera

Traces of Cadmium in Human Scalp Hair Measured by Electrothermal Atomic Absorption Spectrometry with the Slurry Sampling Technique, Pilar Bermejo-Barrera, * Antonio Moreda-Pi#{241}eiro,Teresa Romero-Barbeito, Jorge Moreda-Pi#{241}eiro, and Adela Bermejo-Barrera (Dept. of Anal. Chem., Nutrition, and Bromatob., Faculty of Chem., Univ. of Santiago de Composteba, Av. das Ciencias s/n, E 15706 Santi...

2001
E. Vereda Alonso M. T. Siles Corder

An electrothermal atomization atomic absorption spectrometric method for the determination of traces of nickel atIer extraction of the metal into methyl isobutyl ketone containing 1,5-bis[phenyl(2-pyridylhnethylene] thiocarbonhydrazide is suggested. The chief advantage of the method lies in its maximum allowable aqueous-to-organic phase volume ratio of 37. The method was applied to the determin...

Journal: :Clinical chemistry 1986
P C Ioannou E A Piperaki

We describe a simple fluorometric method for determining aluminum in serum samples by monitoring the rate of reaction of 2-hydroxy-1-naphthaldehyde-p-methoxybenzoylhydrazone with aluminum ions. The emission of the resulting fluorescent metal-chelate formed is measured at 475 nm. Aluminum was measured in the supernate of serum after proteins were removed by precipitation with concentrated nitric...

Journal: :Clinical chemistry 1996
P Borella A Bargellini S Salvioli A Cossarizza

We describe here a novel method to evaluate natural killer (NK) cytolytic activity by use of flameless atomic absorption spectroscopy (GF-AAS). This technique may be adopted for use in laboratories equipped with electrothermal atomic absorption spectrometers. Nonradioactive Cr as Na2CrO4 was used to label target cells (K562), and cell lysis was evaluated by measuring Cr released after 4 h of in...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2014
soleiman bahar razieh zakerian

in this study, we combined ionic liquid-based dispersive liquid liquid micro extraction (il-dllme) with faas for determining the palladium in different real samples at the trace level. 1-hexyl-3-methylimidazolium hexafluorophosphate [hmim][pf6] ionic liquid and 1-(2-pyridylazo) 2-naphthol (pan), were chosen as the extraction solvent and the chelating agent, respectively. the hydrophobic pd–pan ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید