نتایج جستجو برای: electrode response decay

تعداد نتایج: 1103418  

Here, a simple, quick, Low cost and sensitive Potentiometric method is described for tramadol hydrochloride measurement using .PVC membrane electrode based on neutral ligand (E)-N'-(1-(2-hydroxyphenyl)ethylidene)benzohydrazid. Besides, effect of various parameters like ionic additives, membrane solvent and pH on the Potentiometric response of the electrode are investigated. The best electrode p...

ژورنال: سلامت و محیط زیست 2015
احسانی, علی, سبزی, رضا, صحت نیا, بهارک, مناف فر, رامین,

Background and Objectives: Polycyclic aromatic hydrocarbons (PAHs) are widespread environmental contaminants in aquatic environments. These contaminants are generated through oil spills, manufactory processes, and industrial wastes or naturally through the incomplete combustion of coal, oil, gas, and wood waste. Most of these compounds are noted as carcinogenic and mutagenic. Therefore, detecti...

Journal: :analytical and bioanalytical chemistry research 0
mahmoud roushani department of chemistry, university of ilam, ilam, iran somayeh farokhi department of chemistry, university of ilam, ilam, iran

a simple and reliable electrochemical sensor based on cobalt oxide nanoparticles modified glassy carbon electrode (gce/cooxnps) for determination of butylated hydroxyanisole is presented here. the nanoparticles were fabricated by electrodepositing method. the modified electrode shows excellent catalytic activity toward butylated hydroxyanisole oxidation in ph 12.0 phosphate buffer solution (pbs...

Multi-walled carbon nanotubes (MWCNTs) were immobilized on the surface of a glassy carbon electrode (GCE) in the presence of cetyltrimethylammonium bromide (CTAB) to form a MWCNTs-CTAB nanocomposite-modified electrode. The electrocatalytic response of the modified electrode towards tryptophan (Trp) was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The surface...

Journal: :ACS nano 2016
Yujie Zhu Xiulin Fan Liumin Suo Chao Luo Tao Gao Chunsheng Wang

In this study, an FeS2@carbon fiber electrode is developed with FeS2 nanoparticles either embedded in or attached to carbon fibers by using an electrospinning method. By applying this binder-free, metal-current-collector-free FeS2@carbon fiber electrode, both the redox reaction and capacity decay mechanisms for the Li-FeS2 system are revealed by changing the electrolyte (conventional carbonate ...

Journal: :journal of physical & theoretical chemistry 2007
masoud giahi mohammad ali bagherinia azin azari

sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of vo2+ in aqueous solutions. the sol-gel and pvcmembrane electrodes exhibited linear response with nernstian slopes of 29.3 and 28.4 mv perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

Introduction: Increasing the civil incidents including residential fires is a consequence of population growth and development of cities. Residential fire is one of the most important scenarios requiring fast response. Fire response operation encompass various and serious risks for responding team members. Therefore, the present study looks for determining the critical tasks of fire operation r...

Journal: :Journal of the American Chemical Society 2014
Mostafa Baghbanzadeh Felice C Simeone Carleen M Bowers Kung-Ching Liao Martin Thuo Mahdi Baghbanzadeh Michael S Miller Tricia Breen Carmichael George M Whitesides

This paper compares rates of charge transport across self-assembled monolayers (SAMs) of n-alkanethiolates having odd and even numbers of carbon atoms (nodd and neven) using junctions with the structure M(TS)/SAM//Ga2O3/EGaIn (M = Au or Ag). Measurements of current density, J(V), across SAMs of n-alkanethiolates on Au(TS) and Ag(TS) demonstrated a statistically significant odd-even effect on Au...

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaei masood giahi majjid arvand mehran aghaei

tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...

Cobalt has great biological effects on human beings and also other living organisms, hence its determination is very important. In this regard, a novel coated graphite electrode was designed for determination of Co2+ ions by exploiting 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier, for the first time. The foremost function was witnessed from the membrane composition of PVC...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید