نتایج جستجو برای: earthquake excitation
تعداد نتایج: 92263 فیلتر نتایج به سال:
Seismic pounding occurs as a result of lateral vibration and insufficient separation distance between two adjacent structures during earthquake excitation. This research aims to evaluate the stochastic behavior of adjacent structures with equal heights under earthquake-induced pounding. For this purpose, many stochastic analyses through comprehensive numerical simulations are carried out. About...
Recent experimental research has shown that ordinary unbounded steel reinforced elastomeric bearings (SREBs) can be considered as an attractive cost-effective option for the seismic isolation of highway bridges. To further investigate its benefits, the current study is focused on the seismic risk assessment of an optimally designed highway bridge isolated by SREB system. A typical three-span hi...
Experimental Investigation on Excess Pore Water Pressure in Soft Soil-Foundations under Minor Shocks
In this study, shaking table tests are performed to investigate the behavior of excess pore water pressure in different soft soil-foundations of soil-structure interaction (SSI) system. The variation of the behaviors under cycled minor shock is observed. Moreover, The generation and variation mechanism of excess pore water pressure under earthquake excitation in different soft soilfoundations a...
Right-lateral surface displacement reaching 11⁄2 centimeters occurred over a ten-kilometer section of the Imperial fault in association with a magnitude 3.6 earthquake on March 4, 1966, the smallest known earthquake yet associated with surface displacement. The displacement is documented by field observations of en-echelon cracking in pavement and the offset of the white center line of Highway ...
A new type of composite control scheme of disturbance-observer-based control and terminal sliding mode control is proposed for uncertain structural systems. The disturbance are supposed to include two parts. One is generated by an exogenous system, which can represent the harmonic signals with modeling perturbations in structural system. The other part is external excitation in H2-norm context....
Earthquake dynamic response analysis of large complex structures, especially in the presence of nonlinearities, usually turns out to be computationally expensive. In this paper, the methodical developments of a new model order reduction strategy (MOR) based on the proper orthogonal decomposition (POD) method as well as its practical applicability to a realistic building structure are presented....
The importance of the equipment and secondary systems in seismic design and performance evaluation is well recognized and has been the subject of many studies. In all of these studies, earthquake is considered as a single component, and in most of them the primary system is considered as shear building. Most attention has been concentrated on the response of secondary system and its response sp...
In this study, the effect of earthquake frequency content and noise effects on damage detection has been investigated. For this purpose, the damage was defined as nonlinear behavior of beams and columns, and several ground motion records were scaled so that some elements yield under the applied excitation. Then the acceleration response data of each floor obtained using the nonlinear dynamic an...
Dynamic Ratcheting (DR) is a nonlinear dynamic phenomenon occurring in hysteretic damping systems. It means the structural plastic deformation increases asymmetrically in successive cycles under an earthquake excitation. Although it is generally recognized that DR is closely related to the frequency contents of an earthquake excitation applied to thestructure, no targeted analysis has bee...
An understanding of the precise nature of the non -linear response of structures is essential for future improvement of earthquake resistant design procedures. This paper presents a summary of observations of dynamic behaviour which were made on two typical modern buildings during a period of about ten years. These structures underwent numerous tests and experienced three strong earthquake grou...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید