نتایج جستجو برای: dosimetry linear accelerator add on mlc recommissioning
تعداد نتایج: 8622156 فیلتر نتایج به سال:
In order to provide automatic IMRT dose delivery with an add-on MMLC a technical integration of a MMLC system with a linear accelerator was realized. The principle of this integration and the changes and enhancements of the existing hard- and software are briefly described. The system was tested by the automatic delivery of an IMRT plan designed for a head and neck phantom. A verification of do...
background : in spite of clinically useful photon and electron beams, high energy linacs produce secondary particles such as neutrons (photo-neutron production). neutrons have important roles during treatment with high energy photons in terms of protection and dose escalation. in this project, neutron dose equivalent of 18 mv varian accelerators is calculated by tld600 and tld700. materials and...
OBJECTIVES The impact of two multileaf collimator (MLC) systems for linear accelerator-based intracranial stereotactic radiosurgery (SRS) was assessed. METHODS 68 lesions formed the basis of this study. 2.5 mm leaf width plans served as reference. Comparative plans, with identical planning parameters, were based on a 5 mm leaf width MLC system. Two collimation strategies, with collimation fix...
introduction: intensity modulated radiation therapy (imrt) is one of the cancer treatment methods. it is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (mlc). materials and methods: in order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investi...
A methodology for the dosimetric verification of micro-multileaf collimator MMLC) based intensity modulated radiation therapy (IMRT) plans intended for stereotactic applications is described. The procedure is similar to that of conventional IMRT patient-specific quality assurance with some notable exceptions. Relative dosimetry measurements are performed with radiographic film, a commercial fil...
For the purpose of dose measurement using a high-dose rate (192)Ir source, four methods of thermoluminescent dosimeter (TLD) calibration were investigated. Three of the four calibration methods used the (192)Ir source. Dwell times were calculated to deliver 1 Gy to the TLDs irradiated either in air or water. Dwell time calculations were confirmed by direct measurement using an ionization chambe...
Introduction: Intensity modulated radiation therapy (IMRT) is one of the cancer treatment methods. It is important to selectively aim at the target in this way, which can be performed using a multileaf collimator (MLC). Materials and Methods: In order to specifically irradiate the target volume in radiotherapy to reduce the patient absorbed dose, the use of multileaf collimator has been investi...