نتایج جستجو برای: dosimetry
تعداد نتایج: 8115 فیلتر نتایج به سال:
Routine internal dose exposures are typically (in the UK nuclear industry) less than external dose exposures: however, the costs of internal dosimetry monitoring programmes can be significantly greater than those for external dosimetry. For this reason decisions on when to apply routine monitoring programmes, and the nature of these programmes, can be more critical than for external dosimetry p...
The purpose of this study is to evaluate the use of the Dosimetry Check system for patient-specific IMRT QA. Typical QA methods measure the dose in an array dosimeter surrounded by homogenous medium for which the treatment plan has been recomputed. With the Dosimetry Check system, fluence measurements acquired on a portal dosimeter is applied to the patient's CT scans. Instead of making dose co...
UNLABELLED Compared with conventional, whole-organ, S-factor-based dosimetry, 3-dimensional (3D), patient-specific dosimetry better accounts for radionuclide distribution and anatomic patient variability. Its accuracy, however, is limited by the quality of the cumulated activity information that is provided as input. This input has typically been obtained from SPECT and planar imaging studies. ...
The increasing risk of a mass casualty scenario following a large scale radiological accident or attack necessitates the development of appropriate dosimetric tools for emergency response. Luminescence dosimetry has been reliably applied for dose reconstruction in contaminated settlements for several decades and recent research into new materials carried close to the human body opens the possib...
In this article we discuss examples of challenging problems in retrospective dosimetry and describe some promising solutions. The ability to make measurements by accelerator mass spectrometry and luminescence techniques promises to provide improved dosimetry for regions of Belarus, Ukraine and Russian Federation contaminated by radionuclides from the Chernobyl accident. In addition, it may soon...
This work is a comparative study of the dosimetry calculated by Plaque Simulator, a treatment planning system for eye plaque brachytherapy, to the dosimetry calculated using Monte Carlo simulation for an Eye Physics model EP917 eye plaque. Monte Carlo (MC) simulation using MCNPX 2.7 was used to calculate the central axis dose in water for an EP917 eye plaque fully loaded with 17 IsoAid Advantag...
normal 0 false false false en-us x-none fa introduction: in radiation therapy centers across iran, protection of normal tissues is usually accomplished by either cerrobend or lead block shielding. in this study, the influence of these two shielding methods on central axis dose distribution of photon beam a cobalt unit was investigated in clinical conditions. materials and methods: all measureme...
The quest for new materials thermoluminescence (TL) and optically stimulated luminescence (OSL) dosimetry continues to be a central line of research in dosimetry, occupying many groups investigators, is the topic publications. Nevertheless, it has also been area with pitfalls, slow advances our understanding processes, rare improvements over existing materials. Therefore, this paper reviews sta...
A proposed European protocol for dosimetry in digital breast tomosynthesis (DBT) has been applied to estimate the average glandular breast dose (AGD) for two different DBT units. AGD was measured for the examination of series of women and for breast-simulating polymethyl methacrylate (PMMA) phantoms, thus assessing the suitability of the phantoms used for dosimetry in 2D mammography for DBT dos...
The transferability of a measurement protocol from one laboratory to another is an important feature of any mature, standardised protocol. The electron paramagnetic resonance (EPR)-tooth dosimetry technique that was developed in Scientific Center for Radiation Medicine, AMS, Ukraine (SCRM) for routine dosimetry of Chernobyl liquidators has demonstrated consistent results in several inter-labora...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید