نتایج جستجو برای: dosimetric characteristics monte carlo simulation

تعداد نتایج: 1231401  

Journal: :iranian journal of nuclear medicine 2012
pablo aguiar charalampos tsoumpas albert cot javier pavía domènec ros

introduction: the key characteristics of positron emission tomography (pet) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. therefore, accurate quantification is important. however, it can be sensitive to several physical factors. the aim of this investigation is the assessment of the e...

Journal: :Physics in medicine and biology 2005
K Assié I Gardin P Véra I Buvat

Monte Carlo simulations are useful for optimizing and assessing single photon emission computed tomography (SPECT) protocols, especially when aiming at measuring quantitative parameters from SPECT images. Before Monte Carlo simulated data can be trusted, the simulation model must be validated. The purpose of this work was to validate the use of GATE, a new Monte Carlo simulation platform based ...

Hamid Shahbandarzadeh, Khodakaram Salimifard Reza Moghdani

In this paper, the pricing of a European call option on the underlying asset is performed by using a Monte Carlo method, one of the powerful simulation methods, where the price development of the asset is simulated and value of the claim is computed in terms of an expected value. The proposed approach, applied in Monte Carlo simulation, is based on the Black-Scholes equation which generally def...

2013
Sergio Righi Evis Karaj Giuseppe Felici Fabio Di Martino

The Novac7 and Liac are linear accelerators (linacs) dedicated to intraoperative radiation therapy (IORT), which produce high energy, very high dose-per-pulse electron beams. The characteristics of the accelerators heads of the Novac7 and Liac are different compared to conventional electron accelerators. The aim of this work was to investigate the specific characteristics of the Novac7 and Liac...

M. Sohrabpour, N. Babaei Bidmeshki, S.R. Mahdavi,

Background: The purpose of this project was to derive the brachytherapy dosimetric functions described by American Association of Physicists in Medicine (AAPM) TG-43 U1 based on high dose rate 192I sources. Materials and Methods: The method utilized included both simulation of the designed Polymethyl methacrylate (PMMA) phantom using the Monte Carlo of MCNP4C and benchmarking of the simulation ...

A. S. Meigooni M. A. Mosleh-Shirazi R. Faghihi Z. Naghshnezhad,

Background: The Patterson-Parker table was created in 1934 to determine mg-hr required to deliver the prescribed dose to the treatment area. These tables were created using the dosimetric data for 226Ra that was determined in air and were utilized for dose calculations around implants with Ra-equivalent radionuclides such as 137Cs and 192Ir. Therefore, the differences of the tissue attenuation ...

2007
B. Juste M. E. Mota R. Miró S. Gallardo G. Verdú

The present work is devoted to develop a computational model using the Monte Carlo code MCNP5 (Monte Carlo N-Particle) for the simulation of a 6 MV photon beam given by Elekta Precise medical linear accelerator treatment head. The model includes the major components of the multileaf accelerator head and a cube-shaped water tank. Calculations were performed for a photon beam with 10 cm x 10 cm i...

Journal: :مدیریت زنجیره تأمین 0
یاسر سعیدی سوق اردشیر احمدی سعید رمضانی

today according to the competitive conditions, companies try to reduce their inventory level to diminish the costs. in companies inventory management and control should establish a balance between inventory level of spare parts, cost and the risk that arising from absence of part when is needed. it is clear that this level of spare parts inventory affected by facility characteristics and its re...

Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran mehdi momen nezhad ph.d., linear accelerator dept., imam reza hospital, mashhad university of medical sciences, mashhad, iran seyed mohammad hashemi m.sc., medical physics research center, mashhad university of medical sciences, mashhad, iran

introduction: in recent decades, several monte carlo codes have been introduced for research and medical applications. these methods provide both accurate and detailed calculation of particle transport from linear accelerators. the main drawback of monte carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...

2012
Gocha Khelashvili James Chu Aidnag Diaz Julius Turian

The purpose was to study the dosimetric characteristics of the small diameter (≤ 10.0 mm) BrainLAB cones used for stereotactic radiosurgery (SRS) treatments in conjunction with a Varian Trilogy accelerator. Required accuracy and precision in dose delivery during SRS can be achieved only when the geometric and dosimetric characteristics of the small radiation fields is completely understood. Alt...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید