نتایج جستجو برای: dose calculation inhomogeneity phantom tigrt

تعداد نتایج: 427787  

2015
Zhilei Liu Shen Ping Xia Paul Klahr Toufik Djemil

The dosimetric impact of orthopedic metal artifact reduction (O-MAR) on spine SBRT patients has not been comprehensively studied, particularly with spinal prostheses in high-dose gradient regions. Using both phantom and patient datasets, we investigated dosimetric effects of O-MAR in combination of various metal locations and dose calculation algorithms. A physical phantom, with and without a t...

Journal: :iranian journal of radiation research 0
j.w. hong department of radiation oncology, seoul national university bundang hospital, republic of korea h.k. lee department of computer science and engineering, soonchunhyang university, republic of korea j.h. cho department of international radiological science, hallym university of graduate studies, republic of korea

background: this study assessed the clinical usefulness of the solid phantom, which may compensate for the disadvantages of the water phantom, by comparing the radiological doses between the two depending on their depths. materials and methods: the experimental equipment used was a linear accelerator for medical use, water phantom, solid phantom, farmer type ion chamber and electrometer. the di...

Journal: :iranian journal of radiation research 0
gh.r. fallah mohammadi1 department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira n. riyahi alam department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira gh. geraily department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira r. paydar radiation sciences department, faculty of allied medicine, iran university of medical sciences, tehran, iran

background:  this study presents patient specific and organ dose estimation in computed tomography (ct) imaging of thorax directly from patient ct image using monte carlo simulation.  patient's ct image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. materials and methods: egsnrc /beamnrc monte c...

A Chairmadurai C Bhatt D Shrotiya L Chaudhari N Painuly, N Singh, T Verma

Aims: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured results obtained from gafchromic film EBT2.Materials and Methods: Authors employed kailwood (Pinus Wallichiana) to mimic lung. Briefly, seven Kailwood plates, each measuring 25x...

Journal: :The British journal of radiology 1997
M Stasi V Casanova Borca C Fiorino

An important step in the verification of the reliability of portal films as in vivo dosemeters is the evaluation of the agreement between exit dose profiles and optical density profiles measured on the portal film. To test the possibilities of a conventional portal film system in 60Co beams suitable for head and neck irradiation, we verified the agreement between relative exit doses (measured b...

2017
Mojtaba Karbalaee Daryoush Shahbazi-Gahrouei Mohammad B. Tavakoli

An accurate and fast radiation dose calculation is essential for successful radiation radiotherapy. The aim of this study was to implement a new graphic processing unit (GPU) based radiation therapy treatment planning for accurate and fast dose calculation in radiotherapy centers. A program was written for parallel running based on GPU. The code validation was performed by EGSnrc/DOSXYZnrc. Mor...

Journal: :iranian journal of radiation research 0
a. mesbahi medical physics department, medical school and radiation oncology department, imam khomeini hospital, tabriz university of medical sciences, tabriz, iran

background: prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. to study the lung absorbed dose in radiotherapy with small fields,...

Journal: :Medical dosimetry : official journal of the American Association of Medical Dosimetrists 2003
Paul J Keall Jeffrey V Siebers Robert Jeraj Radhe Mohan

The high density and atomic number of hip prostheses for patients undergoing pelvic radiotherapy challenge our ability to accurately calculate dose. A new clinical dose calculation algorithm, Monte Carlo, will allow accurate calculation of the radiation transport both within and beyond hip prostheses. The aim of this research was to investigate, for both phantom and patient geometries, the capa...

2015
Hamideh Nazemi-Gelyan Hadi Hasanzadeh Yasha Makhdumi Sara Abdollahi Fatemeh Akbari Fatemeh Varshoee-Tabrizi Hamzeh Almasrou Alireza Nikoofar Mostafa Rezaei-Tavirani

BACKGROUND Radiotherapy plays an important role in the management of most malignant and many benign primary central nervous system (CNS) tumors. Radiotherapy affects both tumor cells and uninvolved normal cells; so, it is important to estimate absorbed dose to organs at risk in this kind of treatment. The aim of this study was to determine the absorbed dose to chiasma, lens, optic nerve, retina...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید