نتایج جستجو برای: dipping to sub
تعداد نتایج: 10674784 فیلتر نتایج به سال:
We report spectral fitting results for Rosat PSPC observations of the dipping source X 1755-338. These results are consistent with the two-component model that we previously proposed consisting of a blackbody point source plus an extended power law component. Remarkably, the low energy cutoff of the spectrum does not change appreciably in dips, and it can be seen that dipping takes place in the...
We report on the results of a BeppoSAX observation of the dipping LMXRB EXO 0748-676 performed in 2000 November. This is the first simultaneous observation of this source over the 0.1-100 keV energy range. The persistent spectrum is complex and shows a soft excess, which requires the inclusion of an ionized absorber (with a sub-solar abundance of iron). A cutoff power-law is a good fit to the h...
Evaluation of Photocatalytic Activity of Fe Doped TiO2 Thin Film Prepared by sol-gel hot dip-coating
The application of Fe–TiO2 photocatalysis using sol–gel method by hot–dipping technique was investigated. Then, the influences of fabrication parameters, molar ratios of Fe to TiO2, the sol temperature, poly ethylene glycol (PEG) content and the number of dipping cycles on the photocatalytic activity in visible light region were mainly studied. The experimental results revealed the sample with ...
Abnormal nocturnal blood pressure (BP) dipping status may be partly determined by nocturnal sympathetic activity. We studied the effect of nighttime dosing of an alpha(1)-adrenergic blocker, doxazosin, on the BP dipping status of 118 hypertensives, all of whom underwent 24-hour ambulatory BP monitoring before and after treatment. The mean nighttime/daytime ratio of systolic BP was increased (0....
The dipping variations of circadian blood pressure (BP) correlate closely with target-organ damages and cardiovascular events. The aim of this study was to investigate the relationship between BP reverse dipping and the prevalence of stable coronary artery disease (sCAD) in hypertensive patients. Clinical data and the results of 24-hour ambulatory BP monitoring (ABPM) were obtained from 718 hyp...
BACKGROUND Obesity has been linked with abnormal nocturnal dipping of blood pressure (BP) in adults, which in turn is associated with poor cardiovascular outcomes. There are few data regarding abnormal dipping status in the obese pediatric population. The goal of this study was to further describe the relationship between obesity and non-dipping status on ambulatory blood pressure monitor (ABPM...
We report results of analysis of the ASCA observation of 1993, May 7th of the dipping LMXB source XBT0748-676, and propose a new explanation of the spectral evolution in dipping in this source. The behavior of the source was very unusual in that, in the band 1 3 keV, dipping extended around most of the orbital cycle with almost no non-dip intensity evident and the depth of dipping reached 100%....
Monitoring changes in populations of immature (larvae and pupae) mosquitoes are fundamental to determining mosquito-borne disease risk. Dipping is the most common method used to sample immature mosquitoes, but it can be biased towards particular species and instars. We aimed to assess the generality of the findings of Mori (1989), who showed that stirring the water of artificial containers gave...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید