نتایج جستجو برای: digimouse voxel phantom

تعداد نتایج: 31083  

2008
John Hunt Bernardo Dantas Adelaide Azeredo Salvador Allende

The Monte Carlo program Visual Monte Carlo in vivo (VMC in-vivo) was developed and tested over thirteen years at the Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, Brazil. VMC in-vivo has been extensively validated through international intercomparisons and is available for free download. The program simulates the geometry of Whole Body Counter (WBC) and Gamma-Camera Counting sy...

2012
Yinxiangzi Sheng Lixing Liu Jiaqiang Xu Xiaobin Xia

Radiation dose assessment in advanced synchrotron radiation facility is challenging due to the complexity and uncertainties of radiation source terms induced by high energy particle accelerator. Shanghai Synchrotron Radiation Facility (SSRF) is the first third-generation synchrotron facility in China, which was completed in 2009. Radiation dose assessment for workers at SSRF Beam lines is highl...

2013
Matthias Hoffmann Alexander Brost Carolin Jakob Martin Koch Felix Bourier Klaus Kurzidim Joachim Hornegger Norbert Strobel

Minimally invasive interventions often involve tools of curvilinear shape like catheters and guide-wires. If the camera parameters of a fluoroscopic system or a stereoscopic endoscope are known, a 3-D reconstruction of corresponding points can be computed by triangulation. Manual identification of point correspondences is time consuming, but there exist methods that automatically select corresp...

2011
Faraz Kalantari Hossein Rajabi Mohsen Saghari Alireza Emami Ardekani

Introduction: Monte Carlo (MC) is the most common method for simulating virtual SPECT projections. It is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of MC is its long run time. We introduced a model based method considering the effect of body attenuation and i...

2017
Daniëlle Koopman Maureen Groot Koerkamp Pieter L Jager Hester Arkies Siert Knollema Cornelis H Slump Pedro G Sanches Jorn A van Dalen

BACKGROUND Our aim was to evaluate if a recently introduced TOF PET system with digital photon counting technology (Philips Healthcare), potentially providing an improved image quality over analogue systems, can fulfil EANM research Ltd (EARL) accreditation specifications for tumour imaging with FDG-PET/CT. FINDINGS We have performed a phantom study on a digital TOF PET system using a NEMA NU...

Journal: :Journal of radiation research 2009
Marjut Timonen Leena Kankaanranta Nina Lundbom Mika Kortesniemi Tiina Seppälä Mauri Kouri Sauli Savolainen Sami Heikkinen

Proton magnetic resonance spectroscopy (1H MRS) is a potential method to detect and quantify a boron neutron capture therapy 10B-carrier compound, L-p-boronophenylalanine (BPA), in the brain. However, optimal positioning of MRS voxel to capture tissue with maximal BPA concentration can be challenging. Three dimensional proton magnetic resonance spectroscopic imaging (3D 1H MRSI) provides spectr...

2011
Ruben Pauwels Harry Stamatakis Giorgos Manousaridis Adrian Walker Koen Michielsen Hilde Bosmans Ria Bogaerts Reinhilde Jacobs Keith Horner Kostas Tsiklakis

Cone-beam CT (CBCT) has shown to be a useful imaging modality for various dentomaxillofacial applications. However, optimization and quality control of dental CBCT devices is hampered due to the lack of an appropriate tool for image quality assessment. To investigate the application of different image quality parameters for CBCT, a prototype polymethyl methacrylate (PMMA) cylindrical phantom wi...

2010
Vagner Ferreira Cassola Gabriela Hoff

OBJECTIVE: To compare data regarding dosimetry and photons fluence in different breast phantoms, discussing constancy tests and dosimetry applied to mammography. MATERIALS AND METHODS: Different homogeneous breast phantoms and one anthropomorphic voxel phantom were developed for collection of data regarding total absorbed dose in the phantom, absorbed dose in the glandular tissue material-equiv...

Journal: :Medical Physics 2021

Purpose This study explores the possibility of a new method for x-ray computed tomography (CT) calibration by means cross-calibration with proton CT (pCT) data. The proposed aims at more accurate conversion Hounsfield Units (HU) into stopping power ratio (SPR) relative to water be used in proton-therapy treatment planning. Methods X-ray scan was acquired on synthetic anthropomorphic phantom, co...

2011
Sylvia Garny Werner Rühm Maria Zankl Franz M Wagner Herwig G Paretzke

BACKGROUND The Monte Carlo code GEANT4 was used to implement first steps towards a treatment planning program for fast-neutron therapy at the FRM II research reactor in Garching, Germany. Depth dose curves were calculated inside a water phantom using measured primary neutron and simulated primary photon spectra and compared with depth dose curves measured earlier. The calculations were performe...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید