نتایج جستجو برای: chiller
تعداد نتایج: 720 فیلتر نتایج به سال:
Absorption chillers present opportunities to utilize sustainable fuels in the production of chilled water. An assessment of the steam driven absorption chiller at the University of Idaho, was performed to quantify the current exergy destruction rates. Measurements of external processes and flows were used to create a mathematical model. Using engineering equation solver to analyze and identify ...
This study constructed a parameter analysis for improving the energy performance of air-cooled water chillers by altering the angle configuration of the condenser coils. The mathematical models for energy and exergy analyses of the individual components and overall system of air-cooled water chillers are presented. This study investigated the potential enhancement of performance efficiency in a...
This paper presents an engineering application of optimization method for energy conservation in condenser water loop operation in HVAC (Heating, Ventilation and Air Conditioning) systems. Based on the analysis of component model characteristics and interactions within the cooling tower and between towers and chillers, an objective function, which minimizes the operating costs through optimal s...
Genetic Algorithms are employed to optimize the selection of chiller size in a multi-chiller central plant for arbitrary cooling load profiles. The objective of the optimization is to minimize life cycle (capital + operating) costs while keeping all chillers running in good part load conditions to avoid any surge of chillers. The approach has the capability of solving the combinatorial optimiza...
Component and subsystem models used to evaluate the performance of a low-lift cooling system are described. An air-cooled chiller, a hydronic radiant distribution system, variable-speed control, and peak-shifting controls are modeled. A variable-speed compressor that operates over 20:1 speed range and pressure ratios ranging from one to six is at the heart of the chiller. Condenser fan and chil...
The current study was conducted to investigate the optimum stunning voltage and chilling regime with emphasis on reduction in pale, soft and exudative (PSE) pork. The experiments were conducted at seven Korean major pig abattoirs using a total of 91,082 industrial population. Frequencies of PSE meat was found to be significantly (p<0.05) increased as stunning voltage was elevated from 220-240 (...
In the context of indoor building temperature regulation, a controller calculates the inputs for the HVAC system that result in appropriate thermal comfort conditions. Additionally, if electricity prices are time dependent, these control actions will also impact economic expenditures. To improve economic performance, Thermal Energy Storage (TES) is typically used in conjunction with HVAC to tim...
In an energy hub, each energy carrier can be converted to other forms of energy to meet electricity, heating and cooling power demand in an optimal manner. In this study, a framework is presented to optimally design and size interconnected energy hubs. It considers physical constraints on natural gas and electricity networks and environmental issues. The proposed design methodology decides on w...
In the design and operation of cold storage systems, the problems of saving operation cost and improving global economics of whole systems are equally important. Based on optimal control, yearly dynamic cooling loads and payback period, a method to design an optimal scheme is proposed. An approach to calculate and choose the chiller and cold storage tank for the optimal scheme is provided in th...