نتایج جستجو برای: chemical dosimeter

تعداد نتایج: 379992  

Journal: :Physics in medicine and biology 2015
Y De Deene P S Skyt R Hil J T Booth

Three dimensional radiation dosimetry has received growing interest with the implementation of highly conformal radiotherapy treatments. The radiotherapy community faces new challenges with the commissioning of image guided and image gated radiotherapy treatments (IGRT) and deformable image registration software.A new three dimensional anthropomorphically shaped flexible dosimeter, further call...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2001
T T Cheung K N Yu D Nikezic

A true bronchial dosimeter has been designed, consisting of four 400-mesh wire screens and a filter paper. With a face velocity of 3.3 cm s(-1) for home exposure and 4.6 cm s(-1) for mine exposure, the deposition pattern on the wire screens were found to satisfactorily match the variation of the dose conversion factor (in units of mSv WL M(-1)) with the size of radon progeny from 1 to 1000 nm. ...

2010
Susana Lopez-Aparicio Terje Grøntoft Elin Dahlin

96 Since its development, the Early Warning dosimeter for Organic materials (EWO dosimeter) has been used as both a research and general measurement tool for the evaluation of indoor air quality for preservation of cultural heritage artefacts. The EWO dosimeter measures the integrated degradation impact of the environment, comparable to that observed on organic materials due to the synergistic ...

A.R. Farajollahi, F. Pak, M. Horsfield, Z. Myabi,

Background: In this study the basic radiation properties of N-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. Materials and Methods: The NIPAM gel was prepared and irradiated approximately 2 h after manufacturing. The magnetic resonance (MR) images were made 24 h after irradiation. The nuclear magnetic resonance (NMR) respons...

2014
Marc F. Desrosiers

Post-irradiation stability of high-dose dosimeters has traditionally been an important measurement influence quantity. Though the exceptional stability of the alanine dosimeter response with time has rendered this factor a non-issue for routine work, the archival quality of the alanine dosimeter has not been characterized. Here the alanine pellet dosimeter response is measured up to seven years...

Journal: :RADIOISOTOPES 1965

2011
Dheya Sh Al-Othmany Samir Abdul-Majid Mohammad W. Kadi

CR-39 plastic detectors were used for fast neutron dose mapping in the radiotherapy facility at King AbdulAziz University Hospital (KAUH). Detectors were calibrated using a Cf neutron source and a neutron dosimeter. After exposure chemical etching was performed using 6N NaOH solution at 70 C. Tracks were counted using an optical microscope and the number of tracks/cm was converted to a neutron ...

Journal: :BioImpacts : BI 2013
Farideh Pak Alireza Farajollahi Ali Movafaghi Alireza Naseri

INTRODUCTION At present, the polymer gel dosimeter is considered to be the best possible dosimeter for measuring 3-dimesional radiation dose distribution in radiotherapy. These gels are normally toxic; therefore, manufacturing, handling and discarding them require special attention. In order to find less toxic recipe, N-isopropyle acrylamide polymer gel (NIPAM) was introduced. In this study, th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید