نتایج جستجو برای: ceramic head fracture

تعداد نتایج: 279888  

Journal: :the archives of bone and joint surgery 0
valentin neuhaus orthopaedic hand and upper extremity service, yawkey center, suite 2100, massachusetts general hospital, 55 fruit street, boston, ma 02114, usa dimitrios c. christoforou orthopaedic hand and upper extremity service, yawkey center, suite 2100, massachusetts general hospital, 55 fruit street, boston, ma 02114, usa amir reza kachooei orthopedic research center, mashhad university of medical sciences, mashhad, iran jesse b. jupiter orthopaedic hand and upper extremity service, yawkey center, suite 2100, massachusetts general hospital, 55 fruit street, boston, ma 02114, usa david c. ring orthopaedic hand and upper extremity service, yawkey center, suite 2100, massachusetts general hospital, 55 fruit street, boston, ma 02114, usa chaitanya s. mudgal department of orthopedic surgery, massachusetts general hospital, 55 fruit street, boston, ma, 02114 usa.

background:  the purpose of this study was to report the preoperative complaints and postoperative outcome of patients after removal of the radial head prosthesis.   methods:  this is a retrospective review of 14 adult patients (6 females and 8 males) from 2007 to 2011, who underwent radial head prosthesis removal by three surgeons. the average time between implantation and removal was 23 month...

2014
Manuel Jiménez-Melendo Oriol Llena-Blasco August Bruguera Jaime Llena-Blasco Rosa-María Yáñez-Vico Manuel García-Calderón Cristina Vaquero-Aguilar Rocío Velázquez-Cayón José-Luis Gutiérrez-Pérez Daniel Torres-Lagares

OBJECTIVES This study was undertaken to characterize the mechanical response of bare (as-received) and single-layer ceramized zirconia abutments with both internal and external connections that have been developed to enhanced aesthetic restorations. MATERIAL AND METHODS Sixteen zirconia implant abutments (ZiReal Post®, Biomet 3i, USA) with internal and external connections have been analyzed....

2013
Won-Sik Choy Kap Jung Kim Sang Ki Lee Kyoung Wan Bae Yoon Sub Hwang Chang Kyu Park

BACKGROUND This study examines the clinical and radiologic results of ceramic-on-ceramic total hip arthroplasties with regard to wear, osteolysis, and fracture of the ceramic after a minimum follow-up of six years. METHODS We evaluated the results of a consecutive series of 148 primary ceramic-on-ceramic total hip arthroplasties that had been performed between May 2001 and October 2005 in 142...

Journal: :Vojnosanitetski pregled 2012
Nemanja Mirković Aleksandra Spadijer Gostović Zoran Lazić Branka Trifković

BACKGROUND/AIM Fracture toughness determines functional crown strenght and prevents damages on ceramics during mastication. There is a lack of relevant literature data about fracture toughness of crowns made by feather-edge preparation. Mechanical testing of ceramic samples is supposed to show if feather-edge tooth preparation is a successful method for making ceramic crowns without any risk of...

Journal: :British Journal of Surgery 2021

Abstract Introduction Ceramic on ceramic bearing in Total Hip Replacement (THR) is associated with a low but evident risk of linear fracture, which can lead to catastrophic failure if not diagnosed and treated early. Case presentation: A 59-year-old male patient, who underwent ceramic-on-ceramic THR 8 years ago, presented our centre five-week history right hip pain, after he suddenly twisted hi...

2018
Weon-Yoo Kim Myung-Sup Ko Se-Won Lee Kwang-Sub Kim

Purpose This study characterizes the short-term outcomes of ceramic coated metal-on-metal (MoM) large head total hip arthroplasty (THA) in prospectively selected patients aged 70 to 75 years. Materials and Methods Eighteen patients (18 hips) between the ages of 70 and 75-years old with THA using ceramic-coated MoM large heads between June 2014 and December 2014 were evaluated. We prospectivel...

2017
Benjamin A. Winston Ryland P. Kagan Thomas W. Huff

With newer-generation ceramic components used in total hip arthroplasty, component fracture is a rare complication. However rare, when ceramic component fracture does occur, prompt identification and revision is necessary as delay can lead to dramatic failure with resultant metallosis as the extremely hard ceramic debris abrades remaining components. We present a case of a 70-year-old woman wit...

Journal: :The journal of contemporary dental practice 2011
Prasanna M Danappanavar Zinnie Nanda Mummidi Bhaskar Vikas Gowd Mallikarjun Molugu K Amarendher Reddy Rajiv Kumar Reddy M Ashwini Kumar

OBJECTIVE To determine the resistance failure value of nonprecious metal-ceramic restorations at the incisal edge with varying thickness under different application of load. MATERIALS AND METHODS An Ivorian central incisor was prepared to receive metal-ceramic crown, which was further duplicated, invested, casted and 72 metal dies were fabricated in Co-Cr alloy. Metal dies were relieved with ...

Journal: :Stomatologija 2008
Tomas Linkevicius Eugenijus Vladimirovas Simonas Grybauskas Algirdas Puisys Vygandas Rutkunas

PURPOSE The aims of the presented study were to define the fracture rate of implant-supported metal-ceramic restorations delivered in private practice, and to identify if a restoration's contact during eccentric mandible movements has any influence on ceramic fracture rates. MATERIAL AND METHODS Within the period from 2005 to 2008, 251 patients, namely 105 men (42%) and 146 women (58%), recei...

نمودار تعداد نتایج جستجو در هر سال