نتایج جستجو برای: brachytherapy tg 43 formalism

تعداد نتایج: 156742  

2015
Sandeep K. Dhanesar Tze Y. Lim Weiliang Du Teresa L. Bruno Steven J. Frank Rajat J. Kudchadker

MIM Symphony is a recently introduced low-dose-rate prostate brachytherapy treatment planning system (TPS). We evaluated the dosimetric and planning accuracy of this new TPS compared to the universally used VariSeed TPS. For dosimetric evaluation of the MIM Symphony version 5.4 TPS, we compared dose calculations from the MIM Symphony TPS with the formalism recommended by the American Associatio...

2008
R. E. P. Taylor D. W. O. Rogers

This study presents the results of EGSnrc Monte Carlo calculations of the dose distribution surrounding a high dose rate Yb brachytherapy source and 14 high dose rate and pulsed dose rate Ir brachytherapy sources. Energy-weighted spectra of emitted photons, a full set of TG-43 dosimetry parameters, along-away dose tables, and a description of the materials and geometry used for each source are ...

2003
Keith T. Sowards Ali S. Meigooni

Purpose: Recently a new design of a 125 I brachytherapy source was introduced for interstitial seed implants, particularly for prostate seed implants. This new source is the EchoSeedTMModel 6733 125 I brachytherapy source. Due to the differences in source design and manufacturing process from one new source to the next, their dosimetric parameters should be determined according to the American ...

آقامیری, محمودرضا , باغانی, حمیدرضا , حسینی دقیق, محسن , مهدوی, ربیع ,

Background and purpose: Dose calculations in trachea HDR brachytherapy treatment planning systems are greatly based on TG-43 protocol in which, all materials including air inside trachea are treated the same as water. The aim of this study was to survey the effect of air on dose calculations of Flexiplan treatment planning system in trachea HDR brachytherapy. Materials and methods: To ev...

Journal: :Medical physics 2012
Jose Perez-Calatayud Facundo Ballester Rupak K Das Larry A Dewerd Geoffrey S Ibbott Ali S Meigooni Zoubir Ouhib Mark J Rivard Ron S Sloboda Jeffrey F Williamson

PURPOSE Recommendations of the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for high-energy (average energy higher than 50 keV) photon-emitting brachytherapy sources are presented, including the physical characteristics of specific (192)Ir, (137)Cs, and (60)Co source models. METHODS This report has be...

F. Taghdiri, M. Athari, M. Sadeghi, S.H. Hosseini,

Background: The formalism recommended by Task Group 60 (TG-60) of the American Association of Physicists in Medicine (AAPM) is applicable for β sources. Radioactive biocompatible and biodegradable 153Sm glass seed without encapsulation is a β- emitter with a short half life and delivers a high dose rate to the tumor in the millimeter range. In this work the dosimetry parameters of the ...

2017
Brie Cawston‐Grant Hali Morrison Geetha Menon Ron S Sloboda

Model-based dose calculation algorithms have recently been incorporated into brachytherapy treatment planning systems, and their introduction requires critical evaluation before clinical implementation. Here, we present an experimental evaluation of Oncentra® Brachy Advanced Collapsed-cone Engine (ACE) for a multichannel vaginal cylinder (MCVC) applicator using radiochromic film. A uniform dose...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید