نتایج جستجو برای: beam parameters

تعداد نتایج: 682324  

Journal: :Optics letters 2009
Bhaskar Kanseri Shyama Rath Hem Chandra Kandpal

We report an experimental method to determine the generalized Stokes parameters for a pair of points in the cross section of an electromagnetic beam, e.g., an expanded laser beam, with the help of a Young's interferometer and a set of polarizers and quarter-wave plates. The method is investigated theoretically using the electromagnetic spectral interference law. The generalized Stokes parameter...

شعبان, مجتبی , مجلس آرا, محمدحسین ,

In this research we measure some of the optical parameters of Barium Titanate crystal (BaTiO3), such as signal beam gain, coupling constant (exponential gain coefficient), change in index refraction and photorefractive sensitivity, which are very significant for optical data storage. In all experiment, two- wave mixing configuration at 632.8 nm (He- Ne laser) were used. Experimental data f...

ژورنال: سنجش و ایمنی پرتو 2014

In this paper, graphite calorimeter device which is using to calibrate the electron beam of therapy accelerators in the range of the low dose was simulated using the EGS4 calculation code. Then, the electron beam dose distributions were calculated in it and the effects of parameters such as thickness of the calorimeter core, the distance to the source, thickness of air gap around the core, thic...

K Asemi, M Babaei P Safarpour

In this paper, natural frequencies and dynamic response of thick beams made of saturated porous materials resting on viscoelastic foundation are investigated for the first time. The beam is modeled using higher-order beam theory. Kelvin-voight model is used to model the viscoelastic foundation. Distribution of porosity along the thickness is considered in two different patterns, which are symme...

Journal: :journal of rehabilitation in civil engineering 2013
o. yazdanpanah s.m. seyedpoor h. akbarzade bengar

in this paper, the capabilities of displacement curvature derived from static response data for finding the location and severity of damage in euler-bernoulli beams are assessed. static response of a beam is obtained using the finite element modeling. in order to reduce the number of measured nodal displacements, the beam deflection is fitted through a polynomial function using a limited number...

2000
Y. Nosochkov K. A. Thompson

In this note we present results of beam tracking in the NLC extraction line for the NLC option with high luminosity beam parameters (Option H). Particle losses for 0.5 TeV and 1 TeV cms energy beams have been computed and examined as a function of beam offset at the interaction point (IP). Updated tracking results for the NLC Option A are presented as well. Beam Losses in the NLC Extraction Lin...

Journal: :Physical review letters 2013
P Adamson I Anghel C Backhouse G Barr M Bishai A Blake G J Bock D Bogert S V Cao C M Castromonte S Childress J A B Coelho L Corwin D Cronin-Hennessy J K de Jong A V Devan N E Devenish M V Diwan C O Escobar J J Evans E Falk G J Feldman M V Frohne H R Gallagher R A Gomes M C Goodman P Gouffon N Graf R Gran K Grzelak A Habig S R Hahn J Hartnell R Hatcher A Himmel A Holin J Hylen G M Irwin Z Isvan C James D Jensen T Kafka S M S Kasahara G Koizumi M Kordosky A Kreymer K Lang J Ling P J Litchfield P Lucas W A Mann M L Marshak M Mathis N Mayer A M McGowan M M Medeiros R Mehdiyev J R Meier M D Messier D G Michael W H Miller S R Mishra S Moed Sher C D Moore L Mualem J Musser D Naples J K Nelson H B Newman R J Nichol J A Nowak J O'Connor W P Oliver M Orchanian R B Pahlka J Paley R B Patterson G Pawloski S Phan-Budd R K Plunkett X Qiu A Radovic B Rebel C Rosenfeld H A Rubin M C Sanchez J Schneps A Schreckenberger P Schreiner R Sharma A Sousa N Tagg R L Talaga J Thomas M A Thomson G Tinti S C Tognini R Toner D Torretta G Tzanakos J Urheim P Vahle B Viren A Weber R C Webb C White L Whitehead L H Whitehead S G Wojcicki R Zwaska

We report measurements of oscillation parameters from ν(μ) and ν(μ) disappearance using beam and atmospheric data from MINOS. The data comprise exposures of 10.71×10(20) protons on target in the ν(μ)-dominated beam, 3.36×10(20) protons on target in the ν(μ)-enhanced beam, and 37.88 kton yr of atmospheric neutrinos. Assuming identical ν and ν oscillation parameters, we measure |Δm2| = (2.41(-0.1...

The static pull-in instability of beam-type micro-electromechanical systems is theoretically investigated. Two engineering cases including cantilever and double cantilever micro-beam are considered. Considering the mid-plane stretching as the source of the nonlinearity in the beam behavior, a nonlinear size-dependent Euler-Bernoulli beam model is used based on a modified couple stress theory, c...

Journal: :Journal of Physics: Conference Series 2008

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید