نتایج جستجو برای: beam attenuation

تعداد نتایج: 160790  

2001
Junhai Wen Tianfang Li Zhengrong Liang

Single photon emission computed tomography (SPECT) is based on the measurement of radiation emitted by a radiotracer injected into the patient. Because of photoelectric absorption and Compton scatter, the gamma photons are attenuated inside the body before arriving at the detector. A quantitative reconstruction must consider the attenuation, which is usually nonuniform. Novikov has derived an e...

2015
Yunsong Zhao Mengfei Li Li Zeng

In this paper, we propose an iterative beam hardening correction method that is applicable for the case with multiple materials. By assuming that the materials composing scanned object are known and that they are distinguishable by their linear attenuation coefficients at some given energy, the beam hardening correction problem is converted into a nonlinear system problem, which is then solved ...

2014
Qiao Yang Meng Wu Nicole Maass Andreas K. Maier Joachim Hornegger Rebecca Fahrig

In CT, the nonlinear attenuation characteristics of polychromatic X-rays cause beam hardening artifacts in the reconstructed images. When datasets contain multiple materials in the field of scan, the performance of state-of-the-art beam hardening correction approaches is limited by high computational load and reduced correction efficiency. An image based multi-material beam hardening correction...

Journal: :Philosophical transactions. Series A, Mathematical, physical, and engineering sciences 2015
Hyoung Suk Park Yong Eun Chung Jin Keun Seo

This paper presents a mathematical characterization and analysis of beam-hardening artefacts in X-ray computed tomography (CT). In the field of dental and medical radiography, metal artefact reduction in CT is becoming increasingly important as artificial prostheses and metallic implants become more widespread in ageing populations. Metal artefacts are mainly caused by the beam-hardening of pol...

2002
Junhai Wen Tianfang Li Zhengrong Liang

Single-photon emission computed tomography (SPECT) is based on the measurement of radiation emitted by a radiotracer injected into the patient. Because of photoelectric absorption and Compton scatter, the γ photons are attenuated inside the body before arriving at the detector. A quantitative reconstruction must consider the attenuation, which is usually non-uniform. Novikov and Natterer had de...

2000
Kenneth J. Voss

A large set (100 data points at each wavelength) of multispectral beam attenuation, c(X), data at nine wavelengths (440, 450, 490, 520, 535, 550, 565, 630, and 670 nm) is used to develop a spectral model of the beam attenuation coefficient. The relationship c(X) cW(X) = [c(490 nm) cW(490 nm)](1.563 1.149 x 1O-3 X) describes the spectral variation of c(X) where cW(X) is the pure water beam atten...

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

2007
K. Gallmeister

Using QCD-inspired time dependent cross sections for pre-hadrons we provide a combined analysis of available experimental data on hadron attenuation in DIS off nuclei as measured by HERMES with 12 and 27GeV and by EMC with 100 and 280GeV lepton beam energies. We extract the complete four-dimensional evolution of the pre-hadrons using the Jetset-part of Pythia. We find a remarkable sensitivity o...

2010
Gergely Takács

This paper investigates the use of capacitive proximity sensors as sources of contact-free feedback signal measurement for active vibration attenuation applications. An experimental laboratory device is introduced, which consists of a clamped cantilever beam and actuated by bonded piezoelectric actuators. A measurement model is created and experimentally verified for the assessment of beam tip ...

2009
Lucie Dordová Otakar Wilfert

This work is focused on the atmospheric turbulence effect and a new method for determining optical signal attenuation caused by turbulence is presented here. A new method of power budget of optical links comes from optical intensity distribution in a laser beam after the beam passed through turbulent atmosphere. Results given by this method are compared with Rytov approximation which is nowaday...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید