نتایج جستجو برای: applicator stick

تعداد نتایج: 10092  

2015
Marcus Beck Pirus Ghadjar Mirko Weihrauch Susen Burock Volker Budach Jacek Nadobny Jalid Sehouli Peter Wust

BACKGROUND Peritoneal carcinomatosis occurs in different cancer subtypes and is associated with a dismal prognosis. Some doubts remain whether the whole abdomen can be treated by regional hyperthermia, therefore we analyzed feasibility conducting a pilot study. METHODS A simulation of the abdominopelvic heat distribution in 11 patients with peritoneal carcinomatosis was done using the HyperPl...

2009
Kelvin Cheng Masahiro Takatsuka

Vision-based hand pointing interactive systems always assume implicitly that users’ physical pointing accuracy is perfect. However, this may not be the case. We investigated the accuracy provided by users in three pointing strategies. Result showed that pointing inaccuracy can be as high as 239mm at 3 metres away and suggest that the line-up method provides the best accuracy

2015
Amir M. Owrangi Shruti Jolly James M. Balter Yue Cao Katherine E. Maturen Lisa Young Tong Zhu Joann I. Prisciandaro

We present an institutional experience on the clinical implementation of magnetic resonance (MR)-guided vaginal brachytherapy using commercially available solid applicator models. To test the fidelity of solid applicator models to digitize vaginal cylinder applicators, three datasets were evaluated. The first included 15 patients who were simulated with CT alone. Next, a water phantom was used ...

Journal: :Medical physics 2010
Yun Yang Mark J Rivard

PURPOSE Both the AccuBoost D-shaped and round applicators have been dosimetrically characterized and clinically used to treat patients with breast cancer. While the round applicators provide conformal dose coverage, under certain clinical circumstances the breast skin dose may be higher than preferred. The purpose of this study was to modify the round applicators to minimize skin dose while not...

Journal: :International journal of radiation oncology, biology, physics 2002
Sasa Mutic Perry W Grigsby Daniel A Low James F Dempsey William B Harms Richard Laforest Walter R Bosch Tom R Miller

PURPOSE Positron emission tomography (PET) provides physiologic information that is not available from computed tomography (CT) or magnetic resonance studies. PET images may allow more accurate delineation of three-dimensional treatment planning target volumes of brachytherapy gynecologic (GYN) implants. This study evaluates the feasibility of using PET as the sole source of target, normal stru...

سالاری, شاکر, علی نیا, طاهره, غلامی, علی, نژاد رحیم, رحیم,

Background & objectives: Personel who reguraly practice invasive procedures such as blood sample collection are particulary at risk to percutanous injuries. Needle stick injuries present the single gerates risk to medcial personnels. This sudy was undertaken to analyze the problem of needdle sticks injuries among health care workers at teaching hospitals in Urmia in 2008 year.Methods: This cros...

2015
John S. Pruitt

This service provides calibrations for ^^Sr + beta particle ophthalmic applicators. The calibration determines the average surface absorbed-dose rate to water over the active area of the applicator. The technique used is to measure current per unit mass of air at the active surface with an extrapolation ionization chamber, and to convert this into absorbed-dose rate with Bragg-Gray cavity ioniz...

2009
Jenő Pálvölgyi

PURPOSE The dose values computed with the treatment planning system and the in vivo dose measurements with semiconductor detectors in rectum during the high dose rate brachytherapy treatment fraction of the cervix carcinoma are occasionally significantly different. We've investigated the consistency of the Fletcher-Suit applicator geometry and the in vivo rectal probe's position stability durin...

2017
S. Sina R. Faghihi A. S. Meigooni S. Mehdizadeh M. Zehtabian M. A. Mosleh-Shirazi Mohammad Amin Mosleh-Shirazi

*Corresponding author: Dr. Mohammad Amin Mosleh-Shirazi, Department of Radiotherapy and Oncology, Shiraz University of Medical Sciences, Shiraz, Iran. Fax: +98 711 6474320 E-mail: [email protected] Background: The dose rate distribution delivered by a low dose rate 137Cs pellet source, a spherical source used within the source trains of the Selectron gynecological brachytherapy system, was inv...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید