نتایج جستجو برای: anion exchange capacity
تعداد نتایج: 484705 فیلتر نتایج به سال:
A 0.46 cm x 10.0 cm silica monolith column was modified through the in situ covalent attachment of lysine (2,6-diaminohexanoic acid) groups. Due to the zwitterionic nature of the resultant stationary phase, the modified monolithic column contained both cation and anion exchange capacity. In the case of cation exchange, the capacity was found to be relatively low at between 5 and 6.5 micromoles ...
Anion exchange reactions of a number of layered double hydroxides with inorganic anions were investigated. The five LDH systems used in this study were Mg-Al, Ni-Al, Co-Al, Zn-Al and Zn-Cr. Ni-Zn hydroxynitrate and Ni-Zn hydroxyacetate were the LHSs used in this work. In general, all the LDHs and nickel zinc hydroxysalts exhibited higher extent of exchange towards chloride ions. The extent of e...
Of the total one-way chloride fluxes (approximately 1.4 meq/liter cell water X min) in steady state human polymorphonuclear leukocytes bathed in 148 mM Cl media, approximately 70% behaves as self-exchange mediated by a nonselective anion carrier that is not inhibited by stilbene disulfonates. Five properties of this carrier-mediated exchange were investigated: substrate saturation is seen with ...
چکیده ندارد.
Surfactant-Modified MFI-Zeolite Nanosheets (SMZN) were used for the first time as anion-exchangers, in the case of nitrate ion removal. The SMZN material is characterized by high anionic exchange capacity and removal efficiency compared to classical SMZ prepared from clinoptilolite. The SMZN material is easily regenerated and could be probably employed to remove other anionic pollutants.
Most phosphoproteomics experiments rely on prefractionation of tryptic digests before online liquid chromatography-mass spectrometry. This study compares the potential and limitations of electrostatic repulsion-hydrophilic interaction chromatography (ERLIC) and anion-exchange chromatography (AEX). At a pH higher than 5, phosphopeptides have two negative charges per residue and are well-retained...
soil using Cl as a tracer in a 5 mM solution of CaCl2. The AEC ranged from 0.01 to 1.86 cmolc kg 1 with an Many studies have shown that subsoils in the Piedmont region of average value of 0.68 cmolc kg 1. Retardation coeffithe southeastern USA have anion exchange capacity (AEC) and can adsorb anions such as nitrate (NO 3 ). Groundwater discharging to cients were determined from the BTC data and...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید