نتایج جستجو برای: 3d film dosimetry dvh

تعداد نتایج: 284641  

Journal: :Medical physics 2012
Slobodan Devic Nada Tomic Saad Aldelaijan Francois Deblois Jan Seuntjens Maria F Chan Dave Lewis

PURPOSE Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present resu...

2015
Antony L. Palmer David A. Bradley Andrew Nisbet

This work considers a previously overlooked uncertainty present in film dosimetry which results from moderate curvature of films during the scanning process. Small film samples are particularly susceptible to film curling which may be undetected or deemed insignificant. In this study, we consider test cases with controlled induced curvature of film and with film raised horizontally above the sc...

2014
Marta Cremonesi Carlo Chiesa Lidia Strigari Mahila Ferrari Francesca Botta Francesco Guerriero Concetta De Cicco Guido Bonomo Franco Orsi Lisa Bodei Amalia Di Dia Chiara Maria Grana Roberto Orecchia

Radioembolization (RE) of liver cancer with (90)Y-microspheres has been applied in the last two decades with notable responses and acceptable toxicity. Two types of microspheres are available, glass and resin, the main difference being the activity/sphere. Generally, administered activities are established by empirical methods and differ for the two types. Treatment planning based on dosimetry ...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2015
E Grassi F Fioroni V Ferri E Mezzenga M A Sarti T Paulus N Lanconelli A Filice A Versari M Iori

BACKGROUND Targeted radionuclide therapy is a rapidly growing modality. A few commercial treatment planning systems are entering the market. However, some in-house systems are currently developed for a more flexible and customized dosimetry calculation at voxel-level. For this purpose, we developed a novel software, VoxelMed, and performed a comparison with the software STRATOS. METHODS The v...

2014
Michael S. Gossman Samuel S. Hancock Rajat J. Kudchadker Paul R. Lundahl Minsong Cao Christopher S. Melhus

The first quality assurance process for validating dose-volume histogram data involving brachytherapy procedures in radiation therapy is presented. The process is demonstrated using both low dose-rate and high dose-rate radionuclide sources. A rectangular cuboid was contoured in five commercially available brachytherapy treatment planning systems. A single radioactive source commissioned for QA...

Journal: :iranian journal of medical physics 0
seyed mohsen hosseini daghigh radiation medicine department, shahid beheshti university, tehran, iran

introduction interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. the effect of applicator attenuation is not considered in dose calculation method released by aapm-tg43. in this study, the effect of high-dose rate (hdr) brachytherapy esophageal applicator on dose distribution was surveyed in hdr brachytherapy. materials and methods a cylindrical pmma phan...

2013
Yunfei Huang Ryan T. Flynn R. Alfredo C. Siochi John E. Bayouth

The clinical application of the flattening filter-free photon beam (FFF) has enjoyed greater use due to its advantage of reduced treatment time because of the increased dose rate. Its unique beam characteristics, along with the very high-dose rate, require a thorough knowledge of the capability and accuracy in FFF beam modeling, planning, and delivery. This work verifies the feasibility of mode...

Journal: :Physics in medicine and biology 2006
Martin J Butson Tsang Cheung Peter K N Yu

Gafchromic XRCT radiochromic film is a self-developing high sensitivity radiochromic film product which can be used for assessment of delivered radiation doses which could match applications such as computed tomography (CT) dosimetry. The film automatically changes colour upon irradiation changing from a yellow to green/brown colour. The absorption spectra of Gafchromic XRCT radiochromic film a...

Journal: :Medical physics 2009
Slobodan Devic Nada Tomic Christopher G Soares Ervin B Podgorsak

The authors present a radiochromic film dosimetry protocol for a multicolor channel radiochromic film dosimetry system consisting of the external beam therapy (EBT) model GAFCHROMIC film and the Epson Expression 1680 flat-bed document scanner. Instead of extracting only the red color channel, the authors are using all three color channels in the absorption spectrum of the EBT film to extend the...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید