نتایج جستجو برای: x ray detector

تعداد نتایج: 713717  

Journal: :Proceedings of SPIE--the International Society for Optical Engineering 2014
Amit Jain A Panse Daniel R Bednarek Stephen Rudin

Focal spot size is one of the crucial factors that affect the image quality of any x-ray imaging system. It is, therefore, important to measure the focal spot size accurately. In the past, pinhole and slit measurements of x-ray focal spots were obtained using direct exposure film. At present, digital detectors are replacing film in medical imaging so that, although focal spot measurements can b...

2004
F. Santos

The present work describes the development of XHINIA, a novel X-ray detection system able to be deployed both in production and in-service aeronautical environments. The system is based on a portable high-resolution X-ray detection system coupled to an automatic displacement tool. The evaluation of the detection system performances as well as the detection system detectability performances are ...

2005
Mark W. Tate Darol Chamberlain Sol M. Gruner

An area x-ray detector constructed using commercially available “off-the-shelf” parts is described and its performance is characterized. The detector consists of a 1024 1024 pixel charge-coupled device CCD camera optically coupled to x-ray sensitive phosphor screen using a standard 35 mm camera lens. The conversion efficiency, spatial nonuniformity, spatial resolution and the detective quantum ...

2014
Heetak Han Sanggeun Lee Jungmok Seo Chandreswar Mahata Sung Hwan Cho A-Reum Han Keun-Sung Hong Joon-Ho Park Myung-Jin Soh Cheolmin Park Taeyoon Lee

UNLABELLED Although organic-based direct conversion X-ray detectors have been developed, their photocurrent generation efficiency has been limited by recombination of excitons due to the intrinsically poor electrical properties of organic materials. In this report, we fabricated a polymer-based flexible X-ray detector and enhanced the X-ray detection sensitivity using a single-walled carbon nan...

Journal: :Medical physics 2012
David M Hunter George Belev Safa Kasap Martin J Yaffe

PURPOSE Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss, particularly at x-ray energies just above the K-edge of selenium (12.66 keV...

Journal: :Medical physics 2010
Yang Lu Hengyong Yu Guohua Cao Jun Zhao Ge Wang Otto Zhou

PURPOSE In this article, the authors propose a multibeam field emission x-ray (MBFEX) system along with a half-scan fan-beam reconstruction algorithm. METHODS The proposed system consists of a linear CNT-based MBFEX source array, a single large area detector that is divided into same number of segments as the number of x-ray beams, a multihole collimator that aligns each beam with a correspon...

2014
Klaus Giewekemeyer Hugh T. Philipp Robin N. Wilke Andrew Aquila Markus Osterhoff Mark W. Tate Katherine S. Shanks Alexey V. Zozulya Tim Salditt Sol M. Gruner Adrian P. Mancuso

Coherent (X-ray) diffractive imaging (CDI) is an increasingly popular form of X-ray microscopy, mainly due to its potential to produce high-resolution images and the lack of an objective lens between the sample and its corresponding imaging detector. One challenge, however, is that very high dynamic range diffraction data must be collected to produce both quantitative and high-resolution images...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه زنجان 1386

چکیده ندارد.

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2016
Mayuresh Kulkarni Ronald Dendere Fred Nicolls Stef Steiner Tania S Douglas

We present a method for simulating slot-scanning X-ray imaging using the general-purpose Monte Carlo simulation package PENELOPE and penEasy Imaging. Different phantoms can be defined with the PENGEOM package, which defines bodies as combinations of volumes limited by quadric surfaces. The source-detector geometry, the position of the object, the collimator, the X-ray tube properties, the detec...

2014
P. H. Smith

The Chandrayaan-2 Large Area Soft X-ray spectrometer (CLASS) is due to be launched by the Indian Space Research Organisation (ISRO) in 2014. It will map the elemental composition of the lunar surface, building on the Chandrayaan-1 X-ray spectrometer (C1XS) heritage. CLASS will use an array of e2v technologies CCD236 swept charge devices (SCD) providing an active detector area of approximately 6...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید