نتایج جستجو برای: voltage and current harmonics compensation

تعداد نتایج: 16907144  

2013
K.S.Ravi Kumar

The term ‘power quality’ [1-2] refers to the purity of the voltage and current wave-form, and a power quality disturbance is a deviation from the pure sinusoidal form. Harmonics superimposed on the fundamental are one cause of such deviations. Power quality problems [1-2] like voltage harmonics, voltage flickers, voltage sags and voltage swells, current harmonics, current unbalance, reactive cu...

2017
Mothi Ram S. S. Santosh

Objectives: This study proposes a droop controlled voltage unbalance reimbursement technique in an islanded microgrid. Methods/Analysis: The control system is executed in áâ static reference frame work. Here the distributed generators (DGs) inverters are managed appropriately to compensate imbalance in allocating active as well as reactive powers. The control system includes active as well as r...

Journal: :journal of operation and automation in power engineering 2007
h. r. imanijajarmi a. mohamed h. shareef

this paper presents an innovative active power filter design method to simultaneously compensate the current harmonics and reactive power of a nonlinear load. the power filter integrates a passive power filter which is a rl low-pass filter placed in series with the load, and an active power filter which comprises an rl in series with an igbt based voltage source converter. the filter is assumed...

2015
K. Prabha T. Malathi M. Muruganandam

The increasing application of nonlinear loads may cause distribution system power quality issues. This work presents a control of Single-phase Grid Interactive Inverters with nonlinear loads and a technique for Harmonic compensation and power factor correction of nonlinear loads employing Current Controlled Voltage Source Inverter. This work will focus on the design methodology and the analysis...

2012
M. CHANDRA SEKHAR KIRAN BABU

-This paper Discuss about the problem occurring in the medium voltage distribution network such problems reactive power, harmonics and unbalanced load current compensation of Medium voltage Distribution systems. It proposes a simple and inexpensive solution to enhance power quality when a particular connection to the high voltage transmission network. It presents the design of a active power fi...

2014
Soumya I C

Active power filters most of the times are employed for elimination of the harmonics created by non-linear loads in power system and for reactive power compensation of linear and non-linear loads. Compensating current is sent by shunt active power filter (SAF) at Point of Common Coupling (PCC) to mitigate current harmonics in the line. Hence sinusoidal nature of current and voltage waveforms ar...

2014
D. Chinna Kullay Reddy J. Praveen

The Electrical power system contains a wide range of electrical and power electronics components in industrial and commercial applications. The power quality will be affected by various factors like ripples contamination, voltage sag and voltage swells due to the increase in loads of non-linear type like large power electronics converters such as IGBT and GTO, rectifiers, voltage and current gl...

2015
Hanju Cha Jongmin Jo

phase stand-alone inverter is caused by unbalanced load and a dead time distorts inverter output voltage more unsymmetrically. When the inverter supplies unbalanced load, three phase output voltages include unbalanced odd harmonics but dq-axis voltages at synchronous reference frame have even harmonics with different magnitude each other. In this paper, a new compensation method is proposed to ...

2013
N. Arun

Abstract—this paper describes control of 3-phase shunt active filter by using PI, fuzzy and ANFIS controls to improve the power quality and reactive power compensation and harmonic current compensation due to nonlinear loads. The controller is capable of controlling the DC capacitor voltage capable of reference source current. Hysteresis control is used to control the current in PWM inverter. T...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید