نتایج جستجو برای: volar plate

تعداد نتایج: 74614  

Journal: :Revista brasileira de ortopedia 2010
Edgard Novaes de França Bisneto Emygdio José Leomil de Paula Marcelo Rosa de Resende Rames Mattar Júnior Arnaldo Valdir Zumiotti

OBJECTIVE To compare the results from surgical treatment between volar plates with angular stability and orthogonal plates in unstable distal radius fractures, in patients aged over 60 years. METHODS The patients were divided into two groups that were treated with volar plates or orthogonal plates. Clinical and radiographic results were analyzed prospectively. RESULTS The study groups prese...

Journal: :The Journal of hand surgery 2007
Steven I Grindel Mei Wang Matthew Gerlach Linda M McGrady Susan Brown

PURPOSE To test the hypothesis that combining orthogonal fragment-specific fixation with volar fixed-angle fixation provides markedly higher interfragment stability and construct strength compared with volar fixed-angle fixation alone. METHODS Eight matched pairs of fresh cadaveric hand and forearm specimens were potted upright in cement. Flexor and extensor tendons were isolated at insertion...

Journal: :Journal of orthopaedic surgery 2005
K K Wong K W Chan T K Kwok K H Mak

PURPOSE To evaluate the functional and radiological results of treating unstable fractures of the dorsal distal radius with a volar locking plate. METHODS Dorsally displaced distal radial fractures in 30 patients (11 men and 19 women; mean age, 58.6 years) were fixed by volar locking compression plate and followed up for a minimum of one year. RESULTS At final functional assessment, 24 pati...

Journal: :Journal of orthopaedic surgery 2013
Tun-Lin Foo Aaron W T Gan Tamara Soh Winston Y C Chew

PURPOSE To review 9 cases of mechanical failure of the volar locking plate for distal radial fractures. METHODS Records of 374 consecutive patients who underwent volar locking plating for distal radial fractures were reviewed. Mechanical failures of the volar locking plate were defined as plate breakage or bending, screw breakage or loosening, or collapse of articular fragments resulting in i...

2011
Hanae Minegishi Osamu Dohi Soukan An Hidetsugu Sato

BACKGROUND Open reduction and internal fixation using an interlocking plate system has gained popularity for the treatment of dorsally displaced distal radius fractures. PURPOSE To evaluate the functional and radiological results of treating unstable distal radius fractures with the volar locking plate. PATIENTS AND METHODS A retrospective review was conducted of patients from one instituti...

Journal: :The Journal of hand surgery 2015
Hiroshi Yamazaki Shigeharu Uchiyama Masatoshi Komatsu Shun Hashimoto Hiroyuki Kato

PURPOSE To identify risk factors for tendon attrition after volar locking plate fixation of distal radius fractures. METHODS We prospectively assessed attrition of the flexor pollicis longus tendon at volar plate removal in 127 hands in 126 patients. We also evaluated preoperative lateral wrist radiographs, sonographs, and crepitus with flexor pollicis longus tendon motion and compared the de...

2016
Herwig Drobetz Lidia Koval Patrick Weninger Ruth Luscombe Paula Jeffries Stefan Ehrendorfer Clare Heal

AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation. METHODS A prospective, randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomis...

Journal: :Journal of orthopaedic surgery 2014
Louay Al-Mouazzen Daud Tai Shan Chou Georgios Kyriakopoulos John Hambidge

PURPOSE To compare the penetration of the distal screws in relation to the thickness of the distal metaphysis in the polyaxial versus uniaxial volar locking plates. METHODS Records of 78 patients aged 16 to 79 years who underwent open reduction and internal fixation for distal radial fractures (n=81) were reviewed. All fracture subtypes were included. 20 men and 22 women aged 18 to 79 (mean, ...

2017
Hiroyuki Obata Tomonori Baba Kentaro Futamura Osamu Obayashi Atsuhiko Mogami Hideki Tsuji Yoshiaki Kurata Kazuo Kaneko

Recent reports suggest the presence of a rare fracture type for which reduction and fixation cannot be achieved with volar locking plate (VLP). In particular, it is difficult to achieve reduction and fixation with volar lunate facet (VLF) fragments present on the volar ulnar aspect of the lunate facet, because of the anatomical structure and biomechanics in this region. Herein, we report two ch...

Journal: :archives of trauma research 0
kavin khatri department of orthopaedics, ggs medical college faridkot, baba farid university of health sciences, faridkot, india; department of orthopaedics, ggs medical college faridkot, baba farid university of health sciences, faridkot, india. tel: +91-8743878077 vijay sharma department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india kamran farooque department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india vivek tiwari department of orthopaedics, jai prakash narayan apex trauma centre, all india institute of medical sciences, (aiims), new delhi, delhi, india

conclusions the use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications. objectives this study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. patients and methods we reviewed 23 unstable ...

نمودار تعداد نتایج جستجو در هر سال