PURPOSE To determine the accuracy of smart devices (iPods) to measure intermittent noise and integrate a noise dose in the workplace. MATERIALS AND METHODS In experiment 1, four iPods were each paired with a Larson Davis Spark dosimeter and exposed to randomly fluctuating pink noise in a reverberant sound chamber. Descriptive statistics and the mean difference between the iPod and its paired ...
Irradiation of whole blood and blood components before transfusion is currently the only accepted method to prevent Transfusion-Associated Graft-Versus-Host-Disease (TA-GVHD). However, choosing the appropriate technique to determine the dosimetric parameters associated with blood irradiation remains an issue. We propose a dosimetric system based on the standard Fricke Xylenol Gel (FXG) dosimete...
A wide variety of existing combinations of target and filter materials (target/filter combinations) are used in mammography equipment. The patient dose depends on the X-ray quality that is derived from the target/filter combination, and a calibration of the dosimeter that is used in the measurement that corresponds to the specific target/filter combination is necessary. However, dosimeters in m...
Following a previous feasibility study, a photon dosimeter have been constructed by attaching a small piece of BGO scintillator to a low attenuation plastic optical fiber for which the light output is measured with a current-type PMT. The dosimeter model is tested in a Co irradiation chamber in the dose rate range varying from about 50 to 1200 Gy/h. The dose rates are measured at a number of pr...
This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator (linac) for stereotactic radiosurgery treatments. Measurements were made using Gafchromic film (...
The use of gaseous ionization to calculate the absorbed dose of radiation beams is attractive because of its relative ease, suitable response, high accuracy and also cost-effectiveness. This work introduces the design and fabrication of a new parallel plate ionization chamber with two sensitive volumes. A series of standard tests was performed with x-rays, gamma radiation units, and beta source...
Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...
Purpose: The authors report comprehensive commissioning and quality assurance (QA) procedures for Intrabeam, Intra-Operative radiotherapy (IORT) unit. The Intrabeam system miniature X-ray source is a 50 kV and 40 μA unit. Methods: The authors’ tests include measurements of output, beam deflection, isotropy, kVp and mAs measurements, quality index, isodose, reproducibility, linearity, depth dose...