نتایج جستجو برای: tomosynthesis

تعداد نتایج: 1112  

Journal: :Journal of computer assisted tomography 2007
Kai Zeng Hengyong Yu Shiying Zhao Laurie Lee Fajardo Christopher Ruth Zhenxue Jing Ge Wang

Tomosynthesis reconstructs 3-dimensional images of an object from a significantly fewer number of projections as compared with that required by computed tomography (CT). A major problem with tomosynthesis is image artifacts associated with the data incompleteness. In this article, we propose a hybrid tomosynthesis approach to achieve higher image quality as compared with competing methods. In t...

2014
I. Reiser I. Sechopoulos

While the principle of tomosynthesis has been known for almost a century, digital breast tomosynthesis (DBT) is a novel technology that owes its rapid development to the introduction of full-field digital mammography (FFDM). This review article covers the principles and design considerations of DBT, including system geometry. Further, the article provides an in-depth introduction to DBT dosimet...

Journal: :Physics in medicine and biology 2016
K Bliznakova P Russo Z Kamarianakis G Mettivier H Requardt A Bravin I Buliev

The major objective is to adopt, apply and test developed in-house algorithms for volumetric breast reconstructions from projection images, obtained in in-line phase-contrast mode. Four angular sets, each consisting of 17 projection images obtained from four physical phantoms, were acquired at beamline ID17, European Synchroton Radiation Facility, Grenoble, France. The tomosynthesis arc was  ±3...

2006
Predrag R. Bakic Frédéric J. P. Richard Andrew D. A. Maidment

Digital breast tomosynthesis is becoming a clinically attractive modality based on its potential to combine the high resolution and high contrast images, and affordability of digital mammography, with the advantages of 3D image acquisition. In order to facilitate comparison of tomosynthesis images with previous mammographic exams of the same women, there is a need for a method of registering a ...

2006
Predrag R. Bakic Frédéric J. P. Richard Andrew D. A. Maidment

Digital breast tomosynthesis combines the advantages of digital mammography and 3D breast imaging. To facilitate the comparison of new tomosynthesis images with previous mammographic exams of the same woman, there is a need for a method to register a mammogram with tomosynthetic images of the same breast; this is the focus of our paper. We have chosen to approach this multimodality registration...

Journal: :European journal of radiology 2009
James T Dobbins H Page McAdams

Digital tomosynthesis is a radiographic technique that can produce an arbitrary number of section images of a patient from a single pass of the X-ray tube. It utilizes a conventional X-ray tube, a flat-panel detector, a computer-controlled tube mover, and special reconstruction algorithms to produce section images. While it does not have the depth resolution of computed tomography (CT), tomosyn...

Journal: :Radiology management 2005
Andrew Smith

Breast tomosynthesis is a 3-dimensional (3-D) imaging technology that involves acquiring images of a stationary compressed breast at multiple angles during a short scan. The individual images are then reconstructed into a series of thin high-resolution slices that displayed individually or in a dynamic ciné mode. Tomosynthesis can reduce or eliminate the tissue overlap effect. While holding the...

Journal: :Proceedings of SPIE--the International Society for Optical Engineering 2010
Weihua Zhou Xin Qian Jianping Lu Otto Zhou Ying Chen

Digital breast tomosynthesis is a new technique to improve the early detection of breast cancer by providing three-dimensional reconstruction volume of the object with limited-angle projection images. This paper investigated the image reconstruction with a standard biopsy training breast phantom using a novel multi-beam X-ray sources breast tomosynthesis system. Carbon nanotube technology based...

2013
Saeed Seyyedi Kubra Cengiz Mustafa E. Kamasak Isa Yildirim

Digital breast tomosynthesis (DBT) is an innovative imaging modality that provides 3D reconstructed images of breast to detect the breast cancer. Projections obtained with an X-ray source moving in a limited angle interval are used to reconstruct 3D image of breast. Several reconstruction algorithms are available for DBT imaging. Filtered back projection algorithm has traditionally been used to...

Journal: :Radiation protection dosimetry 2010
Gustaf Ullman David R Dance Michael Sandborg Gudrun Alm Carlsson Angelica Svalkvist Magnus Båth

The aim of this work was to calculate synthetic digital chest tomosynthesis projections using a computer simulation model based on the Monte Carlo method. An anthropomorphic chest phantom was scanned in a computed tomography scanner, segmented and included in the computer model to allow for simulation of realistic high-resolution X-ray images. The input parameters to the model were adapted to c...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید