نتایج جستجو برای: titanium alloy ti

تعداد نتایج: 109413  

Journal: :Dental materials journal 2001
M Nakagawa S Matsuya K Udoh

The effects of fluoride concentrations and pH on the corrosion behavior of pure titanium, Ti-6Al-4V, Ti-6Al-7Nb alloys and a new Ti alloy adding palladium, which is expected to promote a repassivation of Ti were examined by anodic polarization and corrosion potential measurements. The amount of dissolved Ti was analyzed by inductively coupled plasma mass spectroscopy. The surface of the specime...

2017
Alicja Kazek-Kęsik Katarzyna Leśniak Ivan S. Zhidkov Danila M. Korotin Andrey I. Kukharenko Seif O. Cholakh Izabela Kalemba-Rec Katarzyna Suchanek Ernst Z. Kurmaev Wojciech Simka

The surface modification of titanium alloys is an effective method to improve their biocompatibility and tailor the material to the desired profile of implant functionality. In this work, technologically-advanced titanium alloys—Ti-15Mo, Ti-13Nb-13Zr and Ti-6Al-7Nb—were anodized in suspensions, followed by treatment in alkali solutions, with wollastonite deposition from the powder phase suspend...

2016
Dong Yang Zhanqiang Liu

Ti-6Al-4V titanium alloy milling has been frequently used in aviation/aerospace industries. Application environments put forward high requirements to create a desired proportion of the constituent phases and fine grain size for optimum mechanical properties of the machined workpiece. However, quantifying microstructural features of dual-phase (α + β) Ti-6Al-4V titanium alloy is difficult due to...

2008
Masafumi Kikuchi Masatoshi Takahashi Osamu Okuno

This study is an investigation of the machinability of experimental Ti-Cu alloys (2, 5, and 10mass% Cu) as new dental titanium alloy candidates for CAD/CAM use. The alloys were slotted with a vertical milling machine and carbide square end mills under two cutting conditions. Their machinability was evaluated through cutting force using a three-component force transducer fixed on the table of th...

2014
Leonardo P. Faverani Wirley G. Assunção Paulo Sérgio P. de Carvalho Judy Chia-Chun Yuan Cortino Sukotjo Mathew T. Mathew Valentim A. Barao

Diabetes and infections are associated with a high risk of implant failure. However, the effects of such conditions on the electrochemical stability of titanium materials remain unclear. This study evaluated the corrosion behavior of a Ti-6Al-4V alloy, with a smooth surface or conditioned by double-acid-etching, in simulated body fluid with different concentrations of dextrose and lipopolysacch...

Journal: :Dental materials journal 2001
H Fukui W Yang S Yamada Y Fujishiro A Morita M Niinomi

Recently, titanium-tantalum alloys have been studied as implant materials for dental and orthopedic surgery. However, titanium and tantalum are difficult to mix by common arc melting and induction melting, because of their high melting point and the marked difference between their densities (Ti: 1,680 degrees C, 4.5 g/cm3, Ta: 2,990 degrees C, 16.6 g/cm3). Thus, the Cold Crucible Levitation Mel...

Journal: :Journal of applied oral science : revista FOB 2003
Wilson José Garbelini Guilherme Elias Pessanha Henriques Manoel Troia Junior Marcelo Ferraz Mesquita Cássia Cilene Dezan

The bond strength by three point bending strength of two metal substrates (commercially pure titanium or grade II, and Ti-6Al-4V alloy or grade V) combined to three distinct low-fusing ceramic systems (LFC) and the nature of porcelain-metal fracture by scanning electron microscopy (SEM) were evaluated. The results were compared to a combination of palladium-silver (Pd-Ag) alloy and conventional...

2009
Adriana Cláudia Lapria Faria Renata Cristina Silveira Rodrigues Rossana Pereira de Almeida Antunes Maria da Gloria Chiarello de Mattos Adalberto Luiz Rosa Ricardo Faria Ribeiro

UNLABELLED Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. OBJECTIVE The aim of the present study was to investigate if temperature variation could affect dental alloy cytotoxicity, testing alloy extracts in an epithelial cell...

Journal: :Acta biomaterialia 2009
M A Baker S L Assis O Z Higa I Costa

Titanium alloys are known to nucleate an apatite layer when in contact with simulated body fluid. This improves the bioactivity of titanium implants and accelerates osseointegration. Promoting the formation of hydroxyapatite on biocompatible metals is, therefore, a very important topic of biomaterials research. In this paper, the formation of hydroxyapatite (HA) on the near-beta Ti-13Nb-13Zr al...

Journal: :مهندسی متالورژی و مواد 0
هادی کریمی احمد زارع مرتضی هادی محسن صادقی علی قاسمی

titanium aluminide and its alloys have been utilized in automotive, aerospace and power industries because of their specific properties such as low density (~ 4 g/cm3), high melting temperature (~ 1460 °c) and excellent high-temperature strength. ti-48al intermetallic compound and its alloys with 1.5, 3 and 5 at.%mn were produced with mechanical alloying of elemental powders for 50 hours. the p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید