نتایج جستجو برای: tg43u1 mcnp4c

تعداد نتایج: 212  

2013
Leila Abdolahi Shiramin Seyed Farhad Masoudi

Thermal neutron capture can be used as a successful technique for detection of non-metallic landmines via the detection of their constituent like nitrogen. Recently, it has been shown that the detection of 10.829 MeV photons from the N(n,γ)N reaction can be used for finding the landmines. In this method a high-energy neutron source like Am-Be inside water as a moderator is used to have thermal ...

2009
Ali Asghar Mowlavi Majed Yazdani

BEBIG Ruthenium-106 ophthalmic plaques have been used for treatment of uveal melanoma, retinoblastoma, melanoma of the iris and other special applications for many years. The plaques consist of a thin film of Ru, a beta emitter, encapsulated in pure silver. The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new model includes detailed description...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه اراک - دانشکده علوم انسانی 1389

از مهمترین ابزار برای مونیتورینگ افراد پرتوکار در محیط های رادیواکتیو دزیمتر فردی می باشد. موضوع این پژوهش تحقیق بر روی دزیمتر نوترون گامایی است که از بج، کارت tld مدل6 7 7 6 و فیلتر کادمیوم تشکیل شده است. هدف این پژوهش تعیین بهترین مکان برای قرار گرفتن فیلتر کادمیوم و اصلاح الگوریتم محاسبه دز است، به نحوی که خطای حاصل از نوترون های حرارتی به حداقل ممکن برسد. میزان نرخ دز آزمایشگاه کالیبراسیو...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه کاشان 1389

در این پایان نامه آهنگ دز هم ارز و شار نوترون ها ی حاصل از چشمه کالیفرنیم-252، برای ضخامت های مختلف از نه ماده آب، پارافین، پلی اتیلن، بتن، آهن، گرافیت، پلی بور، بوروپلی اتیلن وکربید بورون درگستره انرژی10-8 evتا 16 mev با استفاده ازکد محاسباتی mcnp4c که مبتنی بر روش مونت کارلو می باشد، محاسبه و ارائه شده است. از آنجایی که کد mcnp4c تمام برهم کنش های نوترون با ماده را با تمام جزئیات آن ها در نظر...

2002
Hamid Tagziria Neil Roberts Andrew Bennett David J Thomas Martyn Sené

An extensive programme was successfully carried out during the 1995 to 1998 NMS programme to recalibrate and model by Monte Carlo simulations the characteristics of two NPL long counters that are routinely used to standardise neutron fluences [Ta98,Ta00] for neutron energies above 500 keV. The present work is a continuation of it in that the counters responses and effective centres have been me...

2013
Rahim Khabaz Reza Izadi Najafabadi R. I. Najafabadi

This paper presents the evaluation of the geometry correction factor for calibration of Bonner sphere spectrometer (BSS) equipped with the He counter (typical SP9), based on Monte Carlo simulation. Using the MCNP4C code, geometry factors and effectiveness parameters (d) of a 800 polyethylene sphere (r = 10.16 cm) were calculated for 10 different energies and 3 various distances between the sour...

2014
PARISA AKHLAGHI LALEH RAFAT-MOTAVALLI SEYED HASHEM MIRI-HAKIMABAD

The term ‘thermal flux’ implies a Maxwellian distribution of velocity and energy corresponding to the most probable velocity of 2200 m s−1 at 293.4 K. In order to measure the thermal neutron flux density, the foil activation method was used. Thermal neutron flux determination in paraffin phantom by counting the emitted rays of indium foils with two different detectors (Geiger– Muller counter an...

Journal: :iranian journal of radiation research 0
m. momennezhad nuclear medicine research center, emam reza hospital, mashhad university of medical sciences, mashhad, iran m.t. bahreyni toosi medical physics research center, mashhad university of medical sciences, mashhad, iran r. sadeghi nuclear medicine research center, emam reza hospital, mashhad university of medical sciences, mashhad, iran h. gholamhoseinian department of medical physics, medical school, mashhad university of medical sciences, mashhad, iran sh. nasseri department of medical physics, medical school, mashhad university of medical sciences, mashhad, iran

background: the presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. material and methods: in this study the mcnp-4c monte carlo code was used to simulate the 9 mv photon beam generated by a linear accelerator. upon getting a good agreement between the ...

M. Sohrabpour, N. Babaei Bidmeshki, S.R. Mahdavi,

Background: The purpose of this project was to derive the brachytherapy dosimetric functions described by American Association of Physicists in Medicine (AAPM) TG-43 U1 based on high dose rate 192I sources. Materials and Methods: The method utilized included both simulation of the designed Polymethyl methacrylate (PMMA) phantom using the Monte Carlo of MCNP4C and benchmarking of the simulation ...

ژورنال: :کومش 0
پیمان حجازی p. hejazi dept. of medical physics, school of medical sciences, tarbiat modares university, tehran, iranدانشگاه تربیت مدرس، گروه فیزیک پزشکی بیژن هاشمی ملایری b. hashemi-malayeri dept. of medical physics, school of medical sciences, tarbiat modares university, tehran, iranدانشگاه تربیت مدرس، گروه فیزیک پزشکی مجید شهریاری m. shahriari dept. of nuclear engineering, shahid beheshti university, tehran, iranدانشگاه شهید بهشتی، گروه مهندسی هسته ای انوشیروان کاظم نژاد a. kazemnejad dept. of biostatistics, school of medical sciences, tarbiat modares university, tehran, iranدانشگاه تربیت مدرس، گروه آمار حیاتی

سابقه و هدف: تحقیقات پیشین نشان داده اند که روش مونت کارلو جهت ترابرد باریکه های فوتونی در شتاب دهنده های پزشکی روش مناسبی می باشد. باریکه های شبیه سازی شده را می توان جهت اندازه گیری توزیع دز در فانتوم و بدن بیماران استفاده کرد. شناخت توزیع های زاویه ای، انرژی و شعاعی مهم ترین اطلاعات باریکه فوتونی بوده و می تواند جهت کاربرد کلینیکی روش های شبیه سازی مورد استفاده قرار گیرد. اطلاعات فاز- فضا شت...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید