Afshin Akbarzadeh Hossein Ghadiri, Mohammad Rreza Ay, Saied Sarkar

Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter...

Introduction: The head scatter factor (Sc) is important to measurements radiation beam and beam modeling of treatment planning systems used for advanced radiation therapy techniques. This study aimed to investigate the design of a mini-phantom to measurement variations in collimator Sc in the presence of shielding blocks for shaping the beam using different field sizes. <str...

M. Allahverdi, M. Hoseini-Ghahfarokhi, M. Shahriari, M. Zabihzadeh, M.R. Ay, S.R. Mahdavi,

Background: During intensity modulated radiation therapy (IMRT) technique, theoretically, presence of flattening filter (FF) across the beamline of clinical linear accelerator (linac) is not essential to obtain uniform lateral profiles due to intensity modulation of photon beams by multileaf collimators (MLCs). The aim of this study was to investigate the dosimetrical properties of 18 MV photon...

Mansour Zabihzadeh Mohammad Reza Ay, Mojtaba Hoseini- Ghahfarokhi Seyed Rabee Mahdavi

Introduction: During intensity modulated radiation therapy (IMRT) technique, theoretically, presence of flattening filter (FF) across the beamline of clinical linear accelerator (linac) is not essential to obtain uniform lateral profiles due to intensity modulation of photon beams by multileaf collimators (MLCs). The aim of this study was to investigate the dosimetrical propert...

2014
Kyoko Saito Yasuyuki Takahashi Naomi Ogano Hirotaka Shimada Takao Kanzaki Hiroki Okada Kei Yokota Kaori Hatano Yuki Yoshida Tetsuya Higuchi

The acquisition method for planar 67Ga imaging has hardly changed for 30 years. In this study, in order to improve image quality and diagnostic accuracy, we take steps to optimize the acquisition method, and to choose a scatter correction. First, we acquired individual images from the 93 keV, 185 keV, and 300 keV photopeak; then the images were added together and compared to the individual imag...

2011
S. Xu V. Nagarajan R. Sanishvili

In October 2009, a quad, mini-beam collimator was implemented at GM/CA CAT that allowed users to select between a 5, 10, or 20 micron mini-beam or a 300 micron scatter guard for macromolecular crystallography [1]. Initial alignment of each pinhole to the optical axis of each path through the mini-beam collimator is performed under an optical microscope using an alignment jig. Next, the pre-alig...

2011
Mattijs Elschot Johannes Franciscus Wilhelmus Nijsen Alida Johanna Dam Hugo Wilhelmus Antonius Maria de Jong

BACKGROUND Scintillation camera imaging is used for treatment planning and post-treatment dosimetry in liver radioembolization (RE). In yttrium-90 (90Y) RE, scintigraphic images of technetium-99m (99mTc) are used for treatment planning, while 90Y Bremsstrahlung images are used for post-treatment dosimetry. In holmium-166 (166Ho) RE, scintigraphic images of 166Ho can be used for both treatment p...

2005
ANNE LARSSON

2 Cover illustration: The logarithm of a 123 I point spread function. The point source was simulated at 14.0 cm distance from the collimator in air, with the SIMIND version described in Paper V, using parameters corresponding to a GE Millennium MPR with 2.3 × 2.3 m 2 field of view. The grey scale is processed. To Björn, family and friends If you don't care where you are, you ain't lost. ABSTRAC...

2011
Vassiliki Vlachopoulou Christos Antypas Harry Delis Argyrios Tzouras Nikolaos Salvaras Dimitrios Kardamakis George Panayiotakis

BACKGROUND Stereotactic radiosurgery/radiotherapy procedures are known to deliver a very high dose per fraction, and thus, the corresponding peripheral dose could be a limiting factor for the long term surviving patients. The aim of this clinical study was to measure the peripheral dose delivered to patients undergoing intracranial Cyberknife treatment, using the MOSFET dosimeters. The influenc...