نتایج جستجو برای: ray fluorescence xrf

تعداد نتایج: 404863  

برادران دیلمقانی, سعید, رجبی, کامران ,

In this research we apply X-Ray Fluorescence (XRF) method to determine toxic and heavy metals in stack gases that arises from industrial furnaces. Three factories were selected and various samples were collected from their furnaces and smoke-stacker, and the results compared each other.

Journal: :Aging cell 2013
Yulia Pushkar Gregory Robison Brendan Sullivan Sherleen X Fu Meghan Kohne Wendy Jiang Sven Rohr Barry Lai Matthew A Marcus Taisiya Zakharova Wei Zheng

Analysis of rodent brains with X-ray fluorescence (XRF) microscopy combined with immunohistochemistry allowed us to demonstrate that local Cu concentrations are thousands of times higher in the glia of the subventricular zone (SVZ) than in other cells. Using XRF microscopy with subcellular resolution and intracellular X-ray absorption spectroscopy we determined the copper (I) oxidation state an...

2002
S. Cornaby A. Reyes-Mena P. W. Moody T. Hughes A. Stradling T. Grow L. V. Knight

A test bench instrument constructed at MOXTEK, Inc. is capable of simultaneously capturing X-ray diffraction (XRD) and X-ray fluorescence (XRF) information using a charge-coupled device (CCD) as the X-ray detector. NASA is funding the instrument’s construction because of its low-power consumption and compact size; it could be used for in-situ planetary exploration missions for mineral analysis....

2015
Stephen W T Price Kalotina Geraki Konstantin Ignatyev Peter T Witte Andrew M Beale J Fred W Mosselmans

Heterogeneous catalysis performed in the liquid phase is an important type of catalytic process which is rarely studied in situ. Using microfocus X-ray fluorescence and X-ray diffraction computed tomography (μ-XRF-CT, μ-XRD-CT) in combination with X-ray absorption near-edge spectroscopy (XANES), we have determined the active state of a Mo-promoted Pt/C catalyst (NanoSelect) for the liquid-phase...

Journal: :Clinical chemistry 2000
T M Ambrose M Al-Lozi M G Scott

The assessment of past chronic lead exposure is difficult. Chronic lead burden is not always correctly assessed using laboratory-based tests that are useful for acute or recent exposures. We describe a case of suspected chronic lead exposure that illustrated the need for improved and possibly noninvasive methods to determine cumulative lead body burden. X-Ray fluorescence (XRF) is discussed as ...

Journal: :Environmental research 2001
A C Todd R Buchanan S Carroll E L Moshier D Popovac V Slavkovich J H Graziano

In vivo bone lead measurements with 109Cd-based K-shell X-ray fluorescence (XRF) have been used to assess long-term lead exposure in adults. Tibia lead levels were measured in 210 children (106 boys, 104 girls) of 11-12(1/2) years of age in a lead smelter town and in a control (nonexposed) town. Tibia lead levels, methodological uncertainties, and models of some of the factors influencing them ...

2007
John R. Sieber Elizabeth A. Mackey Anthony F. Marlow Rick Paul Ryan Martin

The value assignment of candidate Standard Reference Material (SRM) 57b Silicon Metal provided an opportunity to develop an alkali reaction procedure as a precursor to borate fusion for the preparation of test specimens from the metal powder for X-ray fluorescence spectrometry (XRF). Suggested for this purpose by Blanchette (Adv. X-Ray Anal., 45, 415, 2002), the alkali reaction uses LiOH·H2O to...

2001
Sergei Kirik Igor Yakimov

The paper deals with the application of X-ray fluorescence and diffraction for the routing control of a chemical content of an electrolysis cell in aluminum reduction plants. Among two approaches XRD meets technological requirements on accuracy, time limit and the cost of analysis. XRF demonstrates insufficient accuracy because of sample preparation problem.

2001
Sergei Kirik Igor Yakimov

The paper deals with the application of X-ray fluorescence and diffraction for the routing control of a chemical content of an electrolysis cell in aluminum reduction plants. Among two approaches XRD meets technological requirements on accuracy, time limit and the cost of analysis. XRF demonstrates insufficient accuracy because of sample preparation problem.

2015
Yves Kayser Philipp Hönicke Dariusz Banaś Jean-Claude Dousse Joanna Hoszowska Paweł Jagodziński Aldona Kubala-Kukuś Stanisław H. Nowak Marek Pajek

Depth-profiling measurements by means of synchrotron radiation based grazing XRF techniques, i.e., grazing emission X-ray fluorescence (GEXRF) and grazing incidence X-ray fluorescence (GIXRF), present a promising approach for the non-destructive, sub-nanometer scale precision characterization of ultra shallow ion-implantations. The nanometer resolution is of importance with respect to actual se...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید