When a speaker talks, the consequences of this can both be heard (audio) and seen (visual). A novel visual phonemic restoration task was used to assess behavioral discrimination and neural signatures (event-related potentials, or ERP) of audiovisual processing in typically developing children with a range of social and communicative skills assessed using the social responsiveness scale, a measu...
A specially designed high resolution converging collimator having a focal length of 50 cm has been evaluated for cone beam single photon emission computed tomography (SPECT). The focal region was investigated by imaging a point source placed at the expected focal point and along the central ray of the collimator in front of and behind the focal point. Technetium-99m point source sensitivities m...
A long bore fan beam collimator for imaging the head was designed and constructed for a SPECT system with a rotating scintillation camera. In order to avoid the patient's shoulder during rotation of the camera with a thick camera housing, the long bore design is necessary to allow the collimator to get close to the patient's head for improved spatial resolution. Operating at the minimum radius ...
UNLABELLED This study was performed to investigate the usefulness of a general-purpose medium-energy (ME) collimator for the accurate localization of the sentinel lymph node (SLN) in breast cancer patients. METHODS We compared phantom images and lymphoscintigraphy images obtained under different conditions for a patient with breast cancer. Comparisons were performed between 2 cameras, between...
The importance of collimator R&D with test beam facilities is demonstrated with the example of ILC collimator studies at SLAC End Station A. Related LHC collimator aspects and longer term plans are addressed. Presented at IDTB07, ILC Detector Test Beam workshop, Fermilab, USA, 2007.
Because background radiation in an irradiation room creates a problem with the PG-SPECT (Prompt Gamma-ray Single Photon Emission Computed Tomography) system, which evaluates the absorbed dose for the Boron Neutron Capture Therapy treatment, optimization of a collimator system was performed while taking the shielding of background gamma-rays into consideration. Assuming that a parallel-beam coll...
Collimator systems used in Intensity Modulated Radiation Therapy can form different geometric aperture shapes depending on their physical capabilities. We compare the efficiency of using regular, rotating and dual multileaf collimator (MLC) systems under different combinations of consecutiveness, interdigitation and rectangular constraints. We also create a virtual freeform collimator, which ca...
To more easily estimate accurate values of collimator scatter facor, S(c), we suggest a two-component saturation model that accounts for scatter from the primary collimator and flattening filter and from the collimator jaws. This model, which assumes an exponential distribution of scatter intensity, was tested by in-air measurements using a mini-phantom for 4 MV and 10 MV X-rays of a Clinac 210...
As for the optical measurement, the longer the focal length of collimator is, the less the measurement error is. However, the longer the focal length is, the more difficult the optical design is. It's higher application value to design long focal length collimator with wide-view. The paper designs a collimator with 2000mm focal length, 4 degree field of view and its wavelength range is from 480...
Purpose: Most of the nuclear imaging systems, especially those that are based on single photon emission detection, require the use of a collimatorusually made out of lead (Pb) or some other high Z material such as tungsten (W). Even some PET systems employ some sort of slat-septa collimation, although the important part of PET image formation is done electronically via coincidence detection. Mu...