نتایج جستجو برای: photon dose measurement

تعداد نتایج: 796871  

Haghparast , Abas, Moradhasel, Behrouz, Pashton shayesteh , Sajad, Seidi, Masomeh, Taghi Pour , Mostafa,

Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of three techniques of radiotherapy in the treatment of breast cancer, has been Evaluating the effectiven...

Introduction: Heterogeneity correction is an important parameter in dose calculation for cancer patients where it may be cause inaccuracy in dose calculation as a result of different densities of patients. This study studied the impact of dose calculation of breast cancer patients with and without heterogeneity correction. Material and Methods: Twenty breast cancer patients were treated with Th...

H Gholamhosseinian M Behmadi M Mohammadi, M Momennezhad, M T Bahreyni Toossi, Sh Bayani Sh Naseri,

Background: Given the importance of scattered and low doses in secondary cancer caused by radiation treatment, the point dose of critical organs, which were not subjected to radiation treatment in breast cancer radiotherapy, was measured.Objective: The purpose of this study is to evaluate the peripheral dose in two techniques of breast cancer radiotherapy with two energies. Methods: Eight diff...

Ehsan Mohammadi Hasan Nedaie Mahbod Esfehani, Mahdi Aghili Mahmood Allahverdi Seyed Ali Vaezzadeh

Introduction: This study was designed to evaluate dosimetric parameters such as rectal dose, bladder dose, integral dose (ID), homogeneity index (HI) and conformity index (CI) in various treatment plans for prostate cancer. Materials and Methods: Pelvic computed tomography (CT) scans of 27 patients were acquired and transferred to the RTDosePLAN treatment planning system. For each patient, 8 co...

A. Keshtkar, A. Mesbahi, P. Mehnati,

Background: Monte Carlo method (MC) has played an important role in design and optimization of medical linacs head and beam modeling. The purpose of this study was to compare photon beam features of two commercial linacs, Varian 21EX and Elekta SL-25 using MCNP4C MC code. Materials and Methods: The 6MV photon beams of Varian 21EX and Elekta Sl-25 linacs were simulated based on manufacturers pro...

Journal: :iranian journal of radiation research 0
a. mesbahi medical physics department, medical school, tabriz university of medical sciences- iran

background: monte carlo (mc) modeling of a linear accelerator is a prerequisite for monte carlo dose calculations in external beam radiotherapy. in this study, a simple and efficient model was developed for elekta sl-25 linear accelerator using mcnp4c monte carlo code materials and methods: the head of elekta sl-25 linac was simulated for 6 and 18 mv photon beams using mcnp4c mc code. energy sp...

A.H. Barati, H.A. Nedaie, M. Afkhami, M. Yarahmadi, M.H. Zahmatkesh, W. Parwaie,

Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...

2017
David Hoffman Eunah Chung Clayton Hess Robin Stern Stanley Benedict

PURPOSE The aim of this work was to comprehensively evaluate a new large field ion chamber transmission detector, Integral Quality Monitor (IQM), for online external photon beam verification and quality assurance. The device is designed to be mounted on the linac accessory tray to measure and verify photon energy, field shape, gantry position, and fluence before and during patient treatment. ...

Background: Monte Carlo (MC) modeling of a linear accelerator is a prerequisite for Monte Carlo dose calculations in external beam radiotherapy. In this study, a simple and efficient model was developed for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code Materials and methods: The head of Elekta SL-25 linac was simulated for 6 and 18 MV photon beams using MCNP4C MC code. Energ...