The defocus curve (DC) has become the gold standard method for assessing visual performance at different distances, and hence, to evaluate depth of focus that is provided by modern presbyopia-compensating intraocular lenses are used in cataract surgery. A former study, carried out other authors, reported DC method, based on placing chart far distance using trial negative lenses, underestimated ...
PURPOSE To assess the efficacy of high-frequency ultrasound biomicroscopy (UBM) in improving the accuracy of phakic intraocular lens (pIOL) sizing by increasing the incidence of acceptable postoperative vault. SETTING Multiple private practices, United States. DESIGN Evaluation of diagnostic test or technology. METHODS This prospective multicenter clinical study evaluated eyes having pIOL...
We report a 24-year-old man with bilateral keratoconus in whom Intacs (Addition Technology, Inc.) were implanted in both eyes. The procedure was followed by Artisan toric phakic intraocular lens (Ophtec) implantation to correct the residual myopic and astigmatic refractive error.
We describe a case of modified femtosecond laser settings for cataract extraction in a patient with a posterior chamber phakic intraocular lens (PIOL), to avoid incomplete treatment patterns and treatment displacement. Modification of laser settings (increased depth for the capsulotomy, increased vertical spot spacing for the capsulotomy and increased anterior and posterior capsule safety margi...
PURPOSE To determine the efficacy of the astigmatism correction following toric intraocular lens (IOL) and toric phakic IOL (pIOL) implantation in eyes with no previous ocular surgery and in postkeratoplasty (PKP) eyes. In addition, changes in corneal astigmatism were determined. METHODS Astigmatism was analyzed in 35 eyes with an AcrySof toric IOL, 35 eyes with an Artiflex toric pIOL, 50 eye...
Early elevated intraocular pressure (IOP) following pars plana vitrectomy is a common complication of vitreoretinal surgery and severe pressure elevation may result in visual loss. To investigate the mechanism of IOP elevation following pars plana vitrectomy, a retrospective review of 119 patients (132 eyes) who had undergone vitreoretinal surgery was performed. Ultrasound biomicroscopy (UBM) w...
We report a child who had implantation of an iris-fixated Artisan phakic intraocular lens (IOL) to correct high unilateral myopia to support the therapy of anisometropic amblyopia. After IOL implantation, the patient continued occlusion therapy to further treat the amblyopic eye. One year postoperatively, the best corrected visual acuity in the amblyopic eye was 1.00 and binocular stereovision ...
We report the refractive correction of high astigmatism in one eye of a 23-year-old woman following deep anterior lamellar keratoplasty (DALK) using an Artisan iris-fixated, toric, phakic intraocular lens (IOL). One year after implantation, uncorrected and corrected distance visual acuities were both 20/25, refraction was -1.00 D cylinder, and the endothelial cell count was 1827 cells/mm(2). Ir...
Marfan syndrome, homocystinuria, trauma, and simple ectopia lentis are the most common causes of pediatric lens subluxation. Many patients are best treated with a careful refraction of the phakic or aphakic pupillary axis. For those patients not achieving satisfactory refractive results, endocapsular lensectomy using modern automated vitreous cutting devices is relatively safe and successful. G...