نتایج جستجو برای: passive sampler

تعداد نتایج: 74813  

Journal: :Journal of the Air & Waste Management Association 1992

Polysulfone was investigated as an alternative base-polymer for polymer inclusion membranes (PIM’s) that could withstand harsh environmental conditions and have good transport efficiency of metal ions. PIM’s were prepared using polysulfone as a base polymer and Aliquat 336 as a carrier in the absence of a plasticizer. Chromium (VI) was used as standard to study the extraction efficiency of the ...

Journal: :Marine pollution bulletin 2017
Yann Aminot Angel Belles Claire Alary James W Readman

We report a novel and inexpensive method to provide high resolution vertical measurements of temporally integrated organic contaminants in surface and sub-surface waters in polluted coastal environments. It employs a strip of polyethylene deployed as a passive sampler. Verifications are confirmed via conventional spot sample analyses and against Performance Reference Compound (PRC) calibration ...

Journal: :Water 2022

Wastewater-based epidemiology (WBE) is a surveillance approach used to examine chemical and biological targets within population. Historically, the most common approaches wastewater sampling include grab composite sampling, which can be performed manually or using an automated sampler. However, there are inherent flaws with these methods. They miss analytes due fluctuation events in have high c...

Journal: :Lc Gc North America 2023

LCGC spoke to Leon Barron from Imperial College London, UK, about his work developing a fully miniaturized workflow incorporating three-dimensional-printed passive sampler device (3D-PSD) monitor contaminants of emerging concern (CECs) in river water.

Journal: :Environmental science & technology 2012
Xianming Zhang Cindy Wong Ying D Lei Frank Wania

Passive air samplers (PAS) are simple and cost-effective tools to monitor semivolatile organic compounds in air. Chemical uptake occurs by molecular diffusion from ambient air to a passive sampling medium (PSM). Previous calibration studies indicate that even for the same type of PAS, passive air sampling rates (R, m(3)(air)/d) can be highly variable due to the influence of a number of factors....

2015
Yvette Naudé Peter Gorst-Allman Egmont Rohwer

Water pollution events may arise rapidly, requiring a methodology that is easy to implement, fast to deploy, and sufficiently sensitive to detect the trace presence of hazardous contaminants. A cheap and easy to use silicone rubber (polydimethylsiloxane (PDMS)) miniature passive sampler is described. In order to test the methodology, pollutants were concentrated, in situ, from surface water in ...

2015
Courtney L. Thomas Danny D. Reible Mary Boyce

Volatile losses were measured from polydimethylsiloxane (PDMS) passive samplers during determination of contaminant porewater concentrations in sediments. Volatile losses could occur between the time of retrieval and processing of the passive sampler or in intertidal environments where the passive sampler could potentially be exposed above the water surface at low tide. A model was developed to...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید