نتایج جستجو برای: neonatal monitoring

تعداد نتایج: 377736  

2017
Jae Won Shin Yun Seob Jung Kyungsoo Park Soon Min Lee Ho Seon Eun Min Soo Park Kook In Park Ran Namgung

PURPOSE The aims of this study were to evaluate the safety and pharmacokinetics of levetiracetam (LEV) in neonates with seizures and to establish a population pharmacokinetics (PPK) model by using the software NONMEM. METHODS A retrospective analysis of 18 neonatal patients with seizures, who were treated with LEV, including 151 serum samples, was performed. The mean loading dose was 20 mg/kg...

Journal: :American journal of obstetrics and gynecology 2015
Steven L Clark Janet A Meyers Donna K Frye Thomas Garthwaite Alan J Lee Jonathan B Perlin

OBJECTIVE The objective of the study was to examine the clinical impact of specific fetal monitoring-related practices during induced labor. STUDY DESIGN This was a prospective, nonrandomized study. RESULTS We studied 14,398 women undergoing oxytocin induction of labor. A decrease in the infusion rate of oxytocin in the face of specified category II fetal heart rate tracings was associated ...

Journal: :iranian journal of otorhinolaryngology 0
rasool panahi department of audiology, faculty of rehabilitation, tehran university of medical sciences, tehran, iran. jafari zahra department of basic sciences in rehabilitation, faculty of rehabilitation, rehabilitation research center, tehran sheibanizade abdoreza department of audiology, faculty of rehabilitation, tehran university of medical sciences, tehran, iran. salehi masoud department of biostatistics, faculty of management and medical information, university of medical sciences, tehran, iran. esteghamati abdoreza children's hospital, martyr akbar-abadi, tehran university of medical sciences, tehran, iran. hasani sara department of audiology, faculty of rehabilitation, tehran university of medical sciences, tehran, iran.

introduction: neonatal hyperbilirubinemia is one of the most important factors affecting the auditory system and can cause sensorineural hearing loss. this study investigated the relationship between behavioral hearing thresholds in children with a history of jaundice and the maximum level of bilirubin concentration in the blood.   materials and methods: this study was performed on 18 children ...

Journal: :The Journal of family practice 2010
Craig Barstow Robert Gauer Barbara Jamieson

A continuous electronic fetal monitoring (efm) reduces the risk of neonatal seizure by 50% compared with intermittent auscultation (IA) (strength of recommendation [SOR]: A, systematic review of randomized controlled trials [RCTs]). EFM increases the incidence of cesarean section by 66% and the incidence of operative vaginal delivery by 16% (SOR: A, systematic review of RCTs). It has no effect ...

2014
Hiteshwar Rao Dhruv Saxena Saurabh Kumar Sagar G. V. Bharadwaj S. Amrutur Prem Mony Prashanth Thankachan Kiruba Shankar Suman Rao Swarnarekha Bhat

In this paper we present the design of a wearable temperature sensing device for remote neonatal monitoring. It is designed for continuous and real-time monitoring of the infants in remote rural areas, for the first few weeks after their birth. It is capable of sensing the neonate’s skin temperature with 0.1◦ C accuracy to detect the early onset of hypothermia. The sensed data is transferred se...

Journal: :The Southeast Asian journal of tropical medicine and public health 2003
Wuh-Liang Hwu Ai-Chu Huang Jui-San Chen Kwang-Jen Hsiao Wen-Yu Tsai

Neonatal screening in Taiwan started as a pilot program in 1981. The coverage rate increased to 90% in 1990, and is currently more than 99%. Five diseases are covered in the screening program including congenital hypothyroidism, phenylketonuria, homocystinuria, galactosemia, and glucose-6-phosphate dehydrogenase deficiency. A monitoring system was established at the same time to ensure correct ...

Journal: :Archives of disease in childhood 1986
S K Jivani

Before 1975 in Blackburn in the Premature Baby Unit monitoring facilities were limited. Ambient oxygen monitoring, blood gas analysis, and ventilation were not being performed. Gradually, special care was introduced and from 1978-80 all babies requiring intensive care and long term ventilatory care were transferred to the Regional Neonatal Intensive Care Unit. Not all babies with incipient or e...

2010
K E Boers S M C Vijgen D Bijlenga J A M van der Post D J Bekedam A Kwee P C M van der Salm M G van Pampus M E A Spaanderman K de Boer J J Duvekot H A Bremer T H M Hasaart F M C Delemarre K W M Bloemenkamp C A van Meir C Willekes E J Wijnen M Rijken S le Cessie F J M E Roumen J G Thornton J M M van Lith B W J Mol S A Scherjon

OBJECTIVE To compare the effect of induction of labour with a policy of expectant monitoring for intrauterine growth restriction near term. DESIGN Multicentre randomised equivalence trial (the Disproportionate Intrauterine Growth Intervention Trial At Term (DIGITAT)). SETTING Eight academic and 44 non-academic hospitals in the Netherlands between November 2004 and November 2008. PARTICIPA...

2010
Ioan-Anton Stanculescu

This project describes our approach for automating the calibration stage needed by the Factorial Switching Linear Dynamical System (FSLDS) for neonatal condition monitoring. Using observations collected by the monitoring equipment, the FSLDS proposed by Prof Christopher Williams and Dr John Quinn [22] is highly successful in inferring the probability distributions of both physiological and arti...

Journal: :Archives of disease in childhood. Fetal and neonatal edition 2005
C D Lilley M Stewart C J Morley

This study reports for the first time the use of a respiratory function monitor in a prospective observational cohort of ventilated babies during transport. All 17 babies achieved target transcutaneous carbon dioxide tension within 15 minutes. Fifteen babies had improved ventilation with changes guided by the respiratory function monitor. The monitor was easy to use and useful.

نمودار تعداد نتایج جستجو در هر سال