We have investigated the equilibrium melting point of gallium as a temperature fixed-point at which to calibrate small thermistor thermometers, such as those used to measure temperature in enzyme reaction analysis and other temperature-dependent biological assays. We have determined that the melting temperature of "6N" (99.999% pure) gallium is 29.770 +/- 0.002 degrees C, and that the constant-...
The labial thermistor clip was first introduced as a physiological measure of female sexual arousal almost 30 years ago (Henson, Rubin, Henson, & Williams, 1977); however, only a few studies have subsequently reported on its use. The development of the clip was based on the idea that surface temperature reflects changes in blood volume such as what causes genital tumescence during physiological...
Polymerase chain reaction (PCR) is a method of amplifying DNA which is normally carried out with a thermal cycler. To obtain more accurate and reliable PCR results, the temperature change within the chamber of the thermal cycler needs to be verified and calibrated regularly. Commercially available temperature loggers commonly used for temperature verification tests usually require a graphical u...
Oxygenator arterial outlet blood temperature is routinely measured in the cardiopulmonary bypass (CPB) circuit as a surrogate for the temperature of the arterial blood delivered to sensitive organs such as the brain. The aim of this study was to evaluate the accuracy of the temperature thermistors used in the Terumo Capiox SX25 oxygenator and to compare the temperature measured at the outlet of...
An instrument is described which allows measurements of leaf temperature within about 0.3 C. It consists of a special thermistor probe, a small circuit box, and a standard ammeter. The circuit box can easily be fixed to the meter and contains a battery, which passes 0.3 milliampere through the thermistor, and also contains an integrated circuit amplifier, so that the meter reads 20 C full scale...
In this investigation, Clam, Periwinkle and Oyster shells were separately treated, calcined ball-milled into nano powder. Each powder material was fabricated disc of various lengths in three replicates. each case, the electrical characteristics discs determined. Electrical resistivity values obtained for test samples developed from found to be (6.024 ± 0.009) x 105 Om, (6.823 0.030) (4.916 0.00...
measurements of body temperature and local surface temperature , Our primary concern was acceptance by the patient. As mentioned in the article, the thermistor probe does behave as an RF receiver and cannot be used during RF exposure. The thermistor was not connected to the electronic circuit until approximately 1 min after each exposure, and the thermistor had a thermal response of T1 /2 of ap...
Several RPT sensors have been developed to acquire objective and quantitative pulse waves. These sensors offer improved performance with respect to pressure calibration, size and sensor deployment, but not temperature. Since most pressure sensors are sensitive to temperature, various temperature compensation techniques have been developed, but these techniques are largely inapplicable to RPT se...