نتایج جستجو برای: multi focus fan beam collimator

تعداد نتایج: 906544  

2007
S Yartsev T Kron J Van Dyk

Helical tomotherapy (HT) is a novel treatment approach that combines Intensity-Modulate Radiation Therapy (IMRT) delivery with in-built image guidance using megavoltage (MV) CT scanning. The technique utilises a 6 MV linear accelerator mounted on a CT type ring gantry. The beam is collimated to a fan beam, which is intensity modulated using a binary multileaf collimator (MLC). As the patient ad...

2016
Chenhao Wan Jian Chen Xiahui Tang Qiwen Zhan

Highly efficient fan-out elements are crucial in coherent beam combining architectures especially in coupled laser resonators where the beam passes through the fan-out element twice per round trip. Although the theoretical efficiency is usually less than 86%, the Dammann gratings are ubiquitously utilized in a variety of types of coherent beam combining systems due to the facile design and fabr...

2001
R. Brinkmann Pantaleo Raimondi Andrei Seryi

In the Beam Delivery Systems (BDS) for linear colliders that have been designed or built, collimators (or scrapers) are used to suppress backgrounds due to the beam halo. Off-energy and off-axis particles are stopped on the collimator jaws, physically limiting the acceptance of the system. This concept does not scale well to higher beam energy, higher intensity or lower emittance. The increased...

Journal: :Medical physics 2010
Yang Lu Hengyong Yu Guohua Cao Jun Zhao Ge Wang Otto Zhou

PURPOSE In this article, the authors propose a multibeam field emission x-ray (MBFEX) system along with a half-scan fan-beam reconstruction algorithm. METHODS The proposed system consists of a linear CNT-based MBFEX source array, a single large area detector that is divided into same number of segments as the number of x-ray beams, a multihole collimator that aligns each beam with a correspon...

ژورنال: سنجش و ایمنی پرتو 2016

In order to achieve a thermal neutron beam for neutron radiography applications, a new neutron collimator has been designed, installed and characterized at Tehran Research Reactor (TRR). TRR is a 5 MW, open pool and light water coolant reactor with seven beam tubes. Neutron collimator that is an important part of neutron radiography system was installed in the six inch E beam tube. Collimator d...

2002
D. Onoprienko

Collimation of the multi-MW beams in present linear collider designs is a critical issue. Graphite as a possible collimator material exhibits good mechanical properties but a rather poor electrical conductivity. The resulting resistive wakefields can potentially deteriorate the beam quality. The knowledge of strength and scalings of such wakefields is essential for the design of the collimation...

Journal: :Medical physics 2004
Hengyong Yu Ge Wang

Based on the fan-beam reconstruction formula recently developed by Noo et al. [Phys. Med. Biol. 47, 2525-2546 (2002)] we develop a Feldkamp-type algorithm for the reconstruction of a volume of interest (VOI) from super-short-scan data. With either a circular or spiral scanning locus in our VOI reconstruction scheme, we first estimate fan-beam data from cone-beam data using the popular "cosine c...

2008
André Sopczak

The importance of collimator R&D with test beam facilities is demonstrated with the example of ILC collimator studies at SLAC End Station A. Related LHC collimator aspects and longer term plans are addressed. Presented at IDTB07, ILC Detector Test Beam workshop, Fermilab, USA, 2007.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید