نتایج جستجو برای: monte carlo dosimetry

تعداد نتایج: 79689  

Journal: :basic and clinical cancer research 0
mina salemi master student of physics, dept basic science, islamic azad university central tehran branch, tehran, iran hasan nedaei assistant professor, radiotherapy physics dept, cancer institute, tehran university of medical science, iran s gholami assistant professor, radiotherapy physics dept, cancer institute, tehran university of medical science, iran

background: the purpose of this study was to investigate the application of the monte carlo technique to calculate and analysis of dosimetric parameters for electron beams used in radiotherapy. this technique is based on statistical method and has a powerful role in different radiotherapy aspects. materials and methods: the simulated medical linear accelerator was the varian clinac 2100c. the e...

2013
James C. L. Chow Runqing Jiang Amir M. Owrangi

This study compared a small bone joint dosimetry calculated by the anisotropic analytical algorithm (AAA) and Monte Carlo simulation using megavoltage (MV) photon beams. The performance of the AAA in the joint dose calculation was evaluated using Monte Carlo simulation, and dependences of joint dose on its width and beam angle were investigated. Small bone joint phantoms containing a vertical w...

2012
Sakae Kinase Akram Mohammadi Masa Takahashi

There has been a considerable accumulation of usage of voxel models for internal radiation dosimetry (Xu & Eckerman, 2009 ; Zaidi & Tsui, 2009). The human voxel models of the Reference Male and Reference Female have been introduced and used to evaluate the energy deposition in organs resulting from internal radiation exposures by the International Commission on Radiological Protection (ICRP) (I...

Journal: :Journal of Nuclear Medicine & Radiation Therapy 2018

A. Mostaar, H. Alijanzadeh, M. Mahdavi, M. Zabihzadeh, S.R.M. Mahdavi,

Background: Two protocols of AAPM TG-51 and IAEA TRS-398 were compared followed by a measurement and Monte Carlo simulation of beam quality correction factor, KQ, AAPM TG-51 and IAEA TRS-398 protocols were compared for the absorbed dose to water for DW, and KQ parameters. Materials and Methods: Dose measurements by either protocols were performed with cylindrical and plane parallel ch...

2015
Evaggelos Pantelis Vassiliki Peppa Vasileios Lahanas Eleftherios Pappas Panagiotis Papagiannis

This work presents BrachyGuide, a brachytherapy-dedicated software tool for the automatic preparation of input files for Monte Carlo simulation from treatment plans exported in DICOM RT format, and results of calculations performed for its benchmarking. Three plans were prepared using two computational models, the image series of a water sphere and a multicatheter breast brachytherapy patient, ...

2010
Tzung-Chi Huang Ji-An Liang Thomas Dilling Tung-Hsin Wu Geoffrey Zhang

Thoracic cancer treatment presents dosimetric difficulties due to respiratory motion and lung inhomogeneity. Monte Carlo and deformable image registration techniques have been proposed to be used in four-dimensional (4D) dose calculations to overcome the difficulties. This study validates the 4D Monte Carlo dosimetry with measurement, compares 4D dosimetry of different tumor sizes and tumor mot...

Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید