نتایج جستجو برای: monochromator

تعداد نتایج: 883  

Journal: :Journal of synchrotron radiation 2005
Ulrich Englich Alexander Kazimirov Qun Shen Don H Bilderback Sol M Gruner Quan Hao

To bridge the gap between traditional multilayer and crystal optics a high-resolution multilayer monochromator with a bandwidth of 0.22% has been designed and installed on a bending-magnet beamline (F3) at the Cornell High Energy Synchrotron Source (CHESS) to provide an unfocused monochromatic X-ray beam for protein crystallography experiments. Crystallographic data of excellent quality from a ...

2011
I. Sergueev H.-C. Wille R. P. Hermann D. Bessas Yu. V. Shvyd’ko M. Zając R. Rüffer

A sapphire backscattering monochromator with 1.1 (1) meV bandwidth for hard X-rays (20-40 keV) is reported. The optical quality of several sapphire crystals has been studied and the best crystal was chosen to work as the monochromator. The small energy bandwidth has been obtained by decreasing the crystal volume impinged upon by the beam and by choosing the crystal part with the best quality. T...

2014
F. Frassetto L. Poletto

We present the design of an ultrafast monochromator explicitly designed for extreme-ultraviolet FEL sources, in particular the upcoming FLASH II at DESY. The design originates from the variable-line-spaced (VLS) grating monochromator by adding a second grating to compensate for the pulse-front tilt given by the first grating after the diffraction. The covered spectral range is 6-60 nm, the spec...

2011
Julie Klein Johannes Brauers Til Aach

High fidelity color image acquisition requires an accurate characterization of the camera’s spectral sensitivity curves to perform color calibration or spectral estimation. Several methods have been proposed to perform this task; these include characterizations via test charts, narrowband filters and methods utilizing a monochromator. In most publications, RGB cameras are characterized. In this...

1993
A. M. Khounsary R. K. Smither S. Davey

2 Single crystal silicon has been the material of choice for x-ray monochromators for the past several decades. However, the need for suitable monochromators to handle the high heat load of the next generation synchrotron x-ray beams on the one hand and the rapid and on-going advances in synthetic diamond technology on the other make a compelling case for the consideration of a diamond monochro...

2011
Ali Khounsary

Ali Khounsary Advanced Photon Source Argonne National Laboratory Argonne,IL60649 The high heat load associated with the powerful and concentrated x-ray beams generated by insertion devices (IDs) at a number of present and many of the future (planned or under construction) synchrotron radiation facilities poses a formidable engineering challenge for the design of monochromators and other optical...

Journal: :Microscopy 2013
Ondrej L Krivanek Tracy C Lovejoy Niklas Dellby R W Carpenter

The origins and the recent accomplishments of aberration correction in scanning transmission electron microscopy (STEM) are reviewed. It is remembered that the successful correction of imaging aberrations of round lenses owes much to the successful correction of spectrum aberrations achieved in electron energy loss spectrometers 2-3 decades earlier. Two noteworthy examples of the types of STEM ...

2015
Mercedes Martinson Nazanin Samadi Bassey Bassey Ariel Gomez Dean Chapman

The BioMedical Imaging and Therapy beamlines at the Canadian Light Source are used by many researchers to capture phase-based imaging data. These experiments have so far been limited by the small vertical beam size, requiring vertical scanning of biological samples in order to image their full vertical extent. Previous work has been carried out to develop a bent Laue beam-expanding monochromato...

Journal: :The Journal of Automatic Chemistry 1981
John G. Williams Peter B. Stockwell Michael Holmes Derrick G. Porter

greater than the monochromator's specification, it should be noted that the monochromator used in this study is over ten years old. Because this error is a rather smooth and stable function of wavelength, it is possible to calculate the wavelength of an unknown emission line in a complex sample to an accuracy better than the monochromator specification. The measured wavelength is slightly depen...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید