نتایج جستجو برای: modular stem

تعداد نتایج: 323525  

2010

INTRODUCTION: In current total hip arthroplasty, modularity between the head-neck connection of the femoral stem is well established. More recently, implants with an additional modular connection between the neck and stem have become more popular. The ability to adjust the head centre relative to the stem axis intraoperatively, by connecting the neck in different positions, guarantees high vers...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تبریز - دانشکده مهندسی عمران 1393

در این پژوهش از سه قاب مهاربندی شده با تعداد طبقات دو و چهار و شش طبقه با 5 دهانه استفاده شده و از روش آنالیز استاتیکی غیر خطی(پوش آور) برای تعیین رفتار قابها بهره گرفته شده است.

2012
Rolando González-José Judith Charlin

The specific using of different prehistoric weapons is mainly determined by its physical properties, which provide a relative advantage or disadvantage to perform a given, particular function. Since these physical properties are integrated to accomplish that function, examining design variables and their pattern of integration or modularity is of interest to estimate the past function of a poin...

2015
P. J. Nasr G. S. Keene

We report a unique case of a fractured modular cobalt chromium connection taper Revitan (Zimmer, Warsaw, IN) revision prosthesis. Macroscopic examination revealed a fracture at the diaphyseal-metaphyseal junction of this modular component. This report highlights that fractures can still occur with modern modular prostheses. We are not aware of any published failures of the Revitan revision pros...

2017
Colin D. Canham Pavel I. Muradov Jordan B. Simpson Stephen J. Incavo

This report describes a case of mechanically assisted crevice corrosion and secondary adverse local tissue reaction in a patient following a total hip arthroplasty, utilizing a modular neck (bi-modular) femoral component. Radiographic evaluation demonstrated a well-positioned, stable, cementless arthroplasty. Upon further evaluation, the patient had elevated serum cobalt and chromium levels, an...

2017

The number of revision total hip arthroplasties is predicted to more than double in USA over the next 25 years from an estimated 40800 in 2005 to approximately 96700 in 2030 [1]. Modular femoral stems offer the advantage of adjustment and restoration of joint kinematics including leg length, femoral version and offset, regardless of the exact position of the distal part of the stem [2]. Disadva...

2010
Habiba Bougherara Rad Zdero Suraj Shah Milan Miric Marcello Papini Paul Zalzal Emil H Schemitsch

BACKGROUND The bone loss associated with revision surgery or pathology has been the impetus for developing modular revision total hip prostheses. Few studies have assessed these modular implants quantitatively from a mechanical standpoint. METHODS Three-dimensional finite element (FE) models were developed to mimic a hip implant alone (Construct A) and a hip implant-femur configuration (Const...

2011
E.G Theodorou C.G Provatidis G.C Babis C.S Georgiou P.D Megas

Total Hip Arthroplasty aims at fully recreating a functional hip joint. Over the past years modular implant systems have become common practice and are widely used, due to the surgical options they provide. In addition Big Femoral Heads have also been implemented in the process, providing more flexibility for the surgeon. The current study aims at investigating the effects that femoral heads of...

Journal: :The bone & joint journal 2015
D F Amanatullah J L Howard H Siman R T Trousdale T M Mabry D J Berry

Revision total hip arthroplasty (THA) is challenging when there is severe loss of bone in the proximal femur. The purpose of this study was to evaluate the clinical and radiographic outcomes of revision THA in patients with severe proximal femoral bone loss treated with a fluted, tapered, modular femoral component. Between January 1998 and December 2004, 92 revision THAs were performed in 92 pa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید