نتایج جستجو برای: mcnp x26
تعداد نتایج: 982 فیلتر نتایج به سال:
In previous studies, repeated 5-s exposures of anesthetized pigs to an electronic control device (TASER International's Advanced TASER X26 device) resulted in acidosis and increases in blood electrolytes. In the current study, experiments were performed to investigate the effects of longer continuous exposures to a different electronic-control-device waveform. After intramuscular injection of t...
Radiation Transport Simulation Studies Using MCNP for a Cow Phantom to Determine an Optimal Detector Configuration for a New Livestock Portal. (August 2012) Joe Justina, M.Sc., Mangalore University Co-Chairs of Advisory Committee: Dr. Craig M. Marianno Dr. Sunil S. Chirayath A large radiological accident will result in the contamination of surrounding people, animal, vegetation etc. In such a s...
Standard plume models can underestimate the gamma-ray dose when most of the radioactive material is above the heads of the receptors. Typically, a model is used to calculate the air concentration at the height of the receptor, and the dose is calculated by multiplying the air concentration by a concentration-to-dose conversion factor. Models indicate that if the plume is emitted from a stack du...
Monte Carlo calculations are frequently used to analyse a variety of radiological science applications using low-energy (10-1000 keV) photon sources. This study seeks to create a low-energy benchmark for the MCNP Monte Carlo code by simulating the absolute dose rate in water and the air-kerma rate for monoenergetic point sources with energies between 10 keV and 1 MeV. The analysis compares four...
With the advent of inexpensive computing power over the past two decades, applications of Monte Carlo radiation transport techniques have proliferated dramatically. At Los Alamos, the Monte Carlo codes MCNP5 [1] and MCNPX [2] are used routinely on personal computer platforms for radiation shielding analysis and dosimetry calculations. These codes are attractive for such applications because of ...
INTRODUCTION Law enforcement officers use conducted electrical weapons (CEW) such as the TASER X26 to control violently resistive subjects. There are no studies in the medical literature examining the effects of these weapons on the human stress response. This is the first study to compare the human stress response to conducted electrical weapons, oleoresin capsicum (O.C.), a cold-water tank im...
This study evaluated in vitro the effect of using the operating microscope on repairing furcation perforations using Vitrebond or mineral trioxide aggregate. Forty-six human molar teeth were mounted into a jig attached to a simulated jaw. The teeth were allocated randomly to four groups (n = 10). Furcal perforations were made in the teeth using an ISO 012 round bur in a slow-speed hand-piece. E...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید