نتایج جستجو برای: marginal gap

تعداد نتایج: 180366  

ژورنال: مجله دندانپزشکی 2000
حاج محمودی, محمدرضا , فاضل, اکبر , گرامی پناه, فریده ,

It has been shown that noble alloys require metal collar to resist distortion when subjected to repeat firing cycle of porcelain. Metal collar is undesirable due to esthetic concerns. Since base metal alloys have superior physical properties, it seems that metal collar would not be necessary for obtaining better marginal adaptation of base metal crowns. The Purpose of this study was to evaluate...

2017
P. Kalyani M. Dhanraj Ashish R. Jain

The marginal fit is one of the most important criteria for long-term success of all-ceramic restorations.[1] When considered clinically, a casting becomes acceptable only when the marginal gap between the prepared tooth and the casting is indiscernible both visually and also while probing. The marginal gap may lead to increased retention of plaque. This changes the distribution of microflora as...

Journal: :Brazilian dental journal 2013
Fernanda Pelogia Gwinner Marco Antonio Bottino Lafayete Nogueira-Junior Alvaro Della Bona

The aim of this study was to evaluate the vertical marginal gap of sintered gold copings and metal-ceramic crowns with different finish line preparations: a beveled round shoulder (BRS) and a beveled long chamfer (BLC), testing the null hypotheses that there are no differences in marginal gap regardless of finish line and phase of restoration (coping or crown). Stainless steel master models wer...

F Behdani M. Parirokh M.J Eghbal S Asgari

Introduction: This study was carried out to compare two retrograde filling materials entitled mineral trioxide aggregate (MTA) and Root MTA (RMTA) in regard to their marginal adaptation and surface defects. Method: In this study twenty extracted human teeth were used. In all teeth after cleaning and shaping, the root canals were obturated by gutta-percha and root canal sealer. After that in eac...

Journal: :Restorative dentistry & endodontics 2016
So-Hyun Park Yeon-Jee Yoo Yoo-Jin Shin Byeong-Hoon Cho Seung-Ho Baek

OBJECTIVES The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. MATERIALS AND METHODS A full veneer crown and an mesio-occluso-distal (MOD) inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate...

Journal: :journal of dental research, dental clinics, dental prospects 0
amin salem milani assistant professor, dental and periodontal disease research center, faculty of dentistry, tabriz university of medical sciences, tabriz, iran. saeed rahimi professor of endodontics, department of endodontics, faculty of dentistry, tabriz university of medical sciences, tabriz, iran mohammad froughreyhani associate professor, department of endodontics, faculty of dentistry, tabriz university of medical sciences, tabriz, iran. mahdi vahid pakdel post-graduate student, department of prosthodontics, faculty of dentistry, tabriz university of medical sciences, tabriz, iran

background and aims: in various clinical situations, mineral trioxide aggregate (mta) may come into direct contact with blood. the aim of the present study was to evaluate the effect of exposure to blood on marginal adaptation and surface microstructure of mta. materials and methods: thirty extracted human single-rooted teeth were used in this study. standard root canal treatment was carried ou...

ژورنال: مجله دندانپزشکی 2015
جوکار, زهرا , زکوی, فرامرز, علی‌نژاد, هنگامه ,

  Background and Aims: Marginal fit is one of the key factors in the success of fixed restoration. The aim of this study was to evaluate the fitness of feldespatic crowns made from additional silicon impression and gypsum cast by CAD/CAM.   Materials and Methods: 10 intact extracted upper premolar teeth were used for this experimental study. After preparation of the mounted teeth with radial sh...

Banifatemeh, Alireza, Hashemi, Ehsan, Jalalian, E, Shariaty, Mohammad, zarbakhsh, arash,

Abstract Background & Aim: Marginal adaptation of full ceramic zirconia restorations are one of the important factors in their long-term success and one of the factors affecting marginal adaptation and their strength is the finish line design.This study was conducted to compare the effect of finishline design on the adaptation of monolithic zirconia crowns. Material and methods: In this in-vitr...

2012
F. Farid H. Hajimiragha R. Jelodar A. S. Mostafavi H. Nokhbatolfoghahaie

OBJECTIVE To evaluate the influence of core thickness and fabrication stages on the marginal accuracy of IPS e.max Press crowns. MATERIALS AND METHODS Twenty IPS e.max Press crowns, 1.5mm thick, were fabricated on metal dies. The crowns had two different core thicknesses, 0.8mm for group A and 1mm for group B, ten for each group. Marginal gap was measured after each stage of core fabrication,...

Journal: :The journal of contemporary dental practice 2007
Khalid A Al Wazzan Ahmad A Al-Nazzawi

AIM The purpose of this in vitro study was to investigate the marginal accuracy and internal fit of complete cast crowns and three-unit fixed partial dentures (FPDs) cast with commercially pure titanium (CPTi) and Titanium-Aluminum-Vanadium alloy (Ti-6Al-4V). METHODS AND MATERIALS CPTi and Ti-6Al-4V alloy were used to cast twelve single crowns and twelve three-unit FPDs. A traveling microscop...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید