نتایج جستجو برای: magic f polymer gel dosimeters
تعداد نتایج: 505330 فیلتر نتایج به سال:
This study extends the 'zero scan' method for CT imaging of polymer gel dosimeters to include multislice acquisitions. Multislice CT images consisting of 24 slices of 1.2 mm thickness were acquired of an irradiated polymer gel dosimeter and processed with the zero scan technique. The results demonstrate that zero scan-based gel readout can be successfully applied to generate a three-dimensional...
In this study, using methacrylic and ascorbic acid in gelatin initiated by copper (MAGIC-f) polymer gel after megavoltage energy exposure, the sensitivity of the ultrasound velocity and attenuation coefficient dose-dependent parameters was evaluated. The MAGIC-f polymer gel was irradiated under 1.25 MeV cobalt-60, ranging from 0 to 60 Gy in 2-Gy steps, and received dose uniformity and accuracy ...
introduction: multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. in this work, we investigated mr-based magic gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. materials and methods: a heterogeneous slab phantom including bones was made....
background: in this work investigation of the normoxic pagat polymer gel dosimeter such as sensitivity, the r2-dose response with post time and the percentage depth dose (pdd) of pagat polymer gel dosimeter have been undertaken. materials and methods: using mri, the formulation to give the maximum change in the transverse relaxation rate r2 was determined to be 4.5% n,n'-methylenbis- acryl...
Modern radiotherapy techniques try to deliver the radiation dose by steep gradient. Protocols for these complex treatment delivery techniques are important and extremely sensitive to errors in treatment delivery. To minimize such errors, 3D dosimeters were developed as a relative method for improving dose monitoring and delivery. The aim of this study is to analyze the capability and drawbacks ...
Polymer gels whose NMR and optical properties change when irradiated offer unique advantages for measuring radiation dose distributions. To date, all acrylic polymer gel dosimeters must be manufactured, stored and irradiated in hypoxic conditions which severely limits their use and stability. A new formulation of acrylic dosimeter gel has been developed that responds well in normal atmosphere a...
1. Introduction Magnetic resonance imaging (MRI) can non-invasively and non-destructively probe the magnetization of hydrogen atoms on water molecules in large objects with a high spatial resolution, and in three dimensions. This unique combination of properties is exploited in polymer gel dosimetry since original gel dosimeters, in which viscosity changes were measured and related to the absor...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید